MS6-SV-...-E-10V24
Festo – MS6-SV-...-E-10V24 – 1310b English
55
4.4
Signal contact
The signal contact is a potential-free N/O contact of a semiconductor relay. Through terminals 3 and 4
of the NECA-... multi-pin plug socket, the contact can be picked up in the feedback circuit of a safety
control system.
Note
Operation of the signal contact outside the permitted technical data results in its irre-
parable failure. Compliance with the specification must be ensured through an appro-
priate protective circuit.
Note
Assignment of these contacts is not required to achieve the safety category.
Fig. 10
Feedback signal connection
The diagrams for the switching characteristics can be found in the chapter 14 “Technical data” (with
multi-pin plug socket NECA-S1G9-P9-MP1
Fig. 20; with multi-pin plug socket NECA-
S1G9-P9-MP3/MP5
Fig. 22).
Status of valve
Signal contact
Activation for pressurisation through EN1 and EN2
Open
Activation for exhaust through EN1 and EN2
Closed
Malfunction (red LED flashing)
Open
Supply voltage is not connected
Open
Tab. 3
Switching statuses of the signal contact