MS6-SV-...-E-10V24
Festo – MS6-SV-...-E-10V24 – 1310b English
73
14.5
Switching characteristics of the multi-pin plug sockets NECA-…-MP1,
-MP3 and -MP5
14.5.1
Switching characteristics for multi-pin plug socket NECA-S1G9-P9-MP1
Operating pressure p1
Output pressure p2
+L1: operating voltage
EN1: enable signal 1
EN2: enable signal 2
Signal contacts
Power LED (green)
Error LED (red)
Fig. 20
Input and output switching characteristics in normal operation (when the “Automatic start”
operating mode is set) for multi-pin plug socket NECA-S1G9-P9-MP1
Note
•
Pulses at the inputs EN1 and EN2 from 0 to 24 V of
≤
3 ms duration do not result in
an error message at the safety valve MS6-SV-E.
•
Pulses at the inputs EN1 and EN2 from 24 to 0 V of
≤
12 ms duration do not result in
an error message at the safety valve MS6-SV-E.
The diagrams on the next page show the precise switching characteristics of the Enable signals EN1
and EN2 with a time offset. The maximum reaction time can be derived from the delay between the two
signals.