MS6-SV-...-E-10V24
42
Festo – MS6-SV-...-E-10V24 – 1310b English
1
Safety
1.1
General safety instructions
Note
Loss of the safety function
If measures to handle “common cause failures” (CCF) are not complied with, the safety
function of the soft-start/quick exhaust valve can be impaired.
•
Make sure that the described measures for handling “common cause failures” (CCF)
are complied with (
chap. 2.3 and chap. 14.1).
Note
Loss of the safety function
Non-compliance with the technical data can lead to loss of the safety function.
•
Comply with the technical data.
1.2
Intended use
The electro-pneumatic soft-start/quick exhaust valve is intended solely for reducing pressure quickly
and safely and for building up pressure gently in pneumatic piping systems and terminal equipment in
industry.
The product is a safe, redundant mechatronic system in accordance with the requirements set out in
EN ISO 13849-1+2, in which the pneumatic safety function, safe venting, is guaranteed even in the
event of an error in the valve (e.g. due to wear or contamination).
The MS6-SV-...E-10V24- receives secure enable signals (EN1/EN2) from commercially-available elec-
tronic or electromechanical safety switching devices via its electrical connection (NECA multi-pin plug
socket Sub-D, 9-pin). These safety switching devices monitor the machine's protective devices (e.g.
emergency stop, light curtain, electrical door switch on the protective housing, etc.).
The product is intended for installation in a machine or automated system and must be used exclusively
as follows:
–
in an industrial environment
–
within the limits of the product defined by the technical data (
Chap. 14 Technical data)
–
in original status, without unauthorised modifications
–
in excellent technical condition
–
in standard operation, which also includes rest, set-up and service operation, as well as emergency
operation