5
Mechanical/pneumatic installation
5.1
Mechanical installation
Note
In order to ensure electromagnetic compatibility in accordance with the EMC directive,
observe the following:
•
Observe wall distance of 32 mm (e.g. with the mounting bracket MS6-WPB).
•
Do not install a cable between wall and MS6-SV-E.
Note
Loss of the safety function
If the minimum distance of 15 mm between the silencer and base is not maintained, loss
of the safety function can result.
•
Observe distance of 15 mm below the silencer (
Fig. 13). The free space ensures
trouble free venting.
Information about mounting of the module connector, sub-base and mounting bracket
can be found in the operating instructions enclosed with the relevant accessories.
•
Place the MS6-SV-E as close as possible to the
location of use.
•
The mounting position is any desired.
Fig. 13
Installation