MS6-SV-...-E-10V24
52
Festo – MS6-SV-...-E-10V24 – 1310b English
4.3.2
MS6-SV-E with multi-pin plug socket NECA-S1G9-P9-MP3
Note
The multi-pin plug socket NECA-S1G9-P9-MP3 is intended for conventional circuitry with
electromechanical safety relays. If problems arise in use with bipolar semiconductor
outputs, use the multi-pin plug socket NECA-S1G9-P9-MP5
Fig. 6
Connection to NECA-...-MP3
–
Static enable signals with opposite potentials
–
The time delay of the level change of the enable signals is monitored
–
Behaviour on detection of a cross circuit:
•
MS6-SV-E in the exhausted status: remains in the safe status and goes into malfunction
•
MS6-SV-E in the pressurized status: goes into the safe status and goes into malfunction
Fig. 7
Static enable signals - signal distance
The diagrams for the switching characteristics can be found in the chapter 14 “Technical data”
(
Fig. 22).