10
Dismounting and repair
98
Festo – GDCP-EXCH-KM-KOMP-EN – 1506a – English
10
Dismounting and repair
10.1
Dismounting
Danger
If the planar surface gantry is mounted vertically
Severe crushing from the motor or traverse falling down (Y-axis).
The traverse is held in position with the holding brakes of the motors.
Before starting dismounting:
Position traverse in the lower end position at the end caps and secure it against
uncontrolled movements.
Make sure that no one is located underneath the planar surface gantry during dis
mounting.
Dismount motors only with the planar surface gantry in the horizontal position.
Warning
Electric voltage or components separated when powered.
Unintended starting can trigger unexpected movements.
Injury (death) due to electric shock or severe crushing.
Before performing mounting work, switch off the power supply and secure it against
being switched on again.
Dangerous residual voltage even after the power supply is switched off.
After the supply voltage is switched off, wait at least one minute.
Start work on plugs and interfaces only when the residual voltage has fallen below
60 V.
When pneumatic attachment components are used, compressed air can be stored in the
pneumatic system parts even after switch-off.
Vent pneumatic system parts through corresponding measures.
Note
If the product continues to be used after dismounting:
Place the planar surface gantry in the status at delivery: e.g. attach original trans
port protection aids.
1. Disconnect the planar surface gantry from the higher-order controller.
2. Mount the 2 transport protection aids:
–
horizontal mounting position (
è
–
vertical mounting position (
è
3. For the horizontal mounting position: Also mount the 2 transport plates with the 2 additional trans
port lugs on the X-axes.
4. Dismount the planar surface gantry in reverse sequence, according to the mounting position:
–
horizontal mounting position (
è
–
vertical mounting position (
è