9
Maintenance and care
94
Festo – GDCP-EXCH-KM-KOMP-EN – 1506a – English
9.1
Feed constant
Note
If the absolute exactness of the system worsens (for example, due to temperature fluc
tuations):
Adjust the feet constant in conformity with the documentation
(
è
Description EXCH-…-C… “Commissioning”).
9.2
Cleaning
Note
Clean the system only in exceptional cases. Observe the following:
Do not
clean the guide elements (e.g. guide rails).
9.3
Lubrication
The system is initially lubricated during production. Proper lubrication is required for trouble-free oper
ation and to increase the service life of the linear guides.
Note
Observe specifications for lubrication of the planar surface gantry (
è
Use an appropriate grease gun and corresponding accessories from the Festo cata
logue (
è
www.festo.com/catalogue).
Requirements
Lubricant
ISOFLEX TOPAS NB 52 (K2011-009)
Lubrication interval
[km]
2500
[g]
1
1)
Manufacturer: Klüber Co.
2)
Path specification per axis
3)
Per lubrication nipple (guide carriage)
Tab. 9.1