7
Installation
86
Festo – GDCP-EXCH-KM-KOMP-EN – 1506a – English
7
Installation
7.1
Safety instructions
Warning
Danger of electric shock from voltage sources.
Switch off the supply voltage during the entire installation (switch voltage-free) and
secure it against being switched on again unintentionally.
Only disconnection of the supply voltage in the supply line (fuse or separate switch)
switches voltage off in the connected control system.
Dangerous residual voltage even after the power supply is switched off:
Wait at least one minute after the supply voltage is switched off.
Start work on plugs and interfaces only when the residual voltage has fallen below
60 V.
Only use power sources which guarantee reliable electrical isolation of the operating
voltage in accordance with EN 60204-1.
Connect all PE protective conductors before commissioning.
Observe the regulations of EN 50178 and EN 60204-1 for protective earthing during
installation.
Installation must be performed by a trained technician.
The following qualifications are required:
–
experience with installation and operation of electrical systems.
–
experience with installation and operation of pneumatic systems
(if the pneumatic attachment component is used).