Fitting electrical components
Please note
Leakage currents can damage the measuring system.
S
Make sure that the earth connection
7
is connected to earth potential
(mass cable optional either with eye or with male spade).
The cross-sectional area of the cable must be at least 2.5 mm
2
, the length of
the cable max. 0.5 m.
S
Insert the screw
aD
with cutting thread
provided into the hole for the earth con-
nection
7
.
The electrical contact is then guaranteed
in spite of the anodized layer.
S
Connect the measuring system with the
cable in accordance with the manual for
the SPC... .
The pin assignment is summarized in the following table.
Pin
Designation
Assignment
1
+10 V DC
2
Signal
3
1
3
GND
2
4
4
Screening
2
4
Fig. 29
Fig. 28
aD
7