4
Commissioning
Festo – P.BE-CPX-CTEL-EN – 1411a – English
35
4.6
Parameter
The CTEL master module can be adapted to the respective use situation through the configuration of
various parameters.
In addition, read-only parameters are available for reading out system statuses.
4.6.1
Overview of module parameters
The following table includes an overview of the user-relevant module parameters. The standard set
tings are shown in
bold
characters.
Relative
Address
Mod. par.
R/
W
Bit
7
Bit
6
Bit
5
Bit
4
Bit
3
Bit
2
Bit
1
Bit
0
Module parameter
0
RW
X
Monitoring U
OUT
/U
VAL
0=inactive
1=active
6
RW
X
X
X
X
Error control per I-port:
I-port 1 configuration
I-port 2 configuration
I-port 3 configuration
I-port 4 configuration
00=Use existing device
01=Expect device
10=Port inactive
7
RW
X
S
2
.
1
S
2
.
2
S
1
.
1
S
1
.
2
Behaviour after I-port short circuit.
0=Leave switched off
1=Switch on again
CTEL I/O mode
1)
00=Automatic config.
01=Only outputs (fixed length)
10=Only inputs (fixed length)
11=I/O (fixed length)
CTEL I/O length
1)
00=2 bytes per I-port
01=4 bytes per I-port
10=6 bytes per I-port
11=8 bytes per I-port