4
Commissioning
Festo – P.BE-CPX-CTEL-EN – 1411a – English
41
4.7.2
Observe signal statuses (monitoring)
You can use the operator unit (CPX-MMI) to observe the signal statuses of the connected (and recog
nised) I-port devices.
2:CTEL
Monitoring/Forcing (M)
Diagnostics (D)
Parameters (P)
Fail Safe (F)
Module Data (MD)
2:CTEL:M
Process state
Input Ch 0: 32
Input Ch 1: 0
Input Ch 2: 16
…
Output Ch 0: 4
Output Ch 1: 0
Output Ch 2: 0
…
1
2
1
Channels of the device at the first assigned
I-port (here input module)
2
Channels of the devices at further assigned
I-ports (here output module)
Fig. 4.2
The “Force” function can also be called up via the “Monitoring ...” menu. This function allows you to
force signal statuses during the commissioning phase for test purposes.
The same representation of the I-port devices also applies correspondingly to the “Idle mode” and “Fail
safe” functions.