CESA-GW-AS-PB Description
62
7.1.3.4
Command interface
Only using the IDs of the process data field the PROFIBUS gateway can be used
as M0 AS-i master. By using the command interface (see chap. <DP/V1>) the
functions of a M3 master become available.
A command of the command interface will be edited if the toggle bit T
1
has
changed. This way the same command can be used repeatedly.
16-bit data
byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
1
slave 31-n/8, channel 1, high byte
2
slave 31-n/8, channel 1, low byte
3
slave 31-n/8, channel 2, high byte
4
slave 31-n/8, channel 2, low byte
…
…
n-3
slave 31, channel 3/slave 31B, channel 1, high byte
n-2
slave 31, channel 3/slave 31B, channel 1, low byte
n-1
slave 31, channel 4/slave 31B, channel 2, high byte
n
slave 31, channel 4/slave 31B, channel 2, low byte
Tab. 7-17.
Request
byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
1
command
2
T
circuit
3
request parameter byte 1
…
…
36
request parameter byte 34
Answer
byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
1
command (mirrored)
2
result
3
response parameter byte 1
…
…
34
response parameter byte 32
Tab. 7-18.
1. A
T bit
(toggle bit) is only needed to execute two commands directly one after the other.