STEP 2
Diagram 1
Make a 2-
5⁄8
” wide by 3-
7⁄8
” high cutout in
the desired control location.
Do not oversize or undersize the cutout.
STEP 3
Diagram 2
Route the control cable (provided with the
control) from the wall cutout to the steam
generator. Connect one end of the cable to
the steam generator connector.
NOTE:
The connector is keyed with the
flat facing up. The control cable is the same
at both ends.
IMPORTANT NOTE:
Be careful not to
strain, staple, pinch or otherwise damage
the control cable. Route cable as required
to permit replacement. Do not route cable
inside conduit together with power lines or
close to hot water or steam piping.
STEP 4
Diagram 3
Firmly connect the other end of the cable to
the control. Turn on power to the steam
generator and test the control to verify
correct connections. Test per the
instructions on pages 10-15. With
verification of proper control function,
proceed to Step 5.