Installation & Operating Instructions
______________________________________________________________
10
5.
Route the end of the probe cable with the tem-
perature probe through the wall into the steam
room as shown in Diagram 2.
IMPORTANT NOTE:
Do not strain, staple,
pinch or otherwise damage the probe cable.
6.
With a minimal length of the cable exposed
apply silicone (provided) to the hole in the wall
as required to create a moisture seal as shown
in Diagram 2.
7.
Push the temperature cable and probe into
hole as required to leave minimum 1/4",
maximum 1/2" of the bulb exposed as shown
in Diagram 3.
Insure a minimum of 1/4" of
the temperature probe is exposed to the air.
Failure to do so may interfere with the ability
to sense temperature and may result in
excessive steam room temperatures.
The exposed area of the tempera-
ture probe must be free of silicone or any materials
or obstructions that prevent direct exposure to the
steam room air. Failure to do so may interfere with
the ability to sense temperature and may result in
excessive steam room temperatures.
NOTE:
For Illustrative Purposes Only.
Drawings Not to Scale
WARNING
!
WARNING
!
Silicone Sealant
Cable
Wall
1⁄4" minimum
1⁄2" maximum
DIAGRAM 2
DIAGRAM 3
Sectional View
Installed Remote
Temperature Probe
showing a minimum
of 1/4” of the probe
exposed to steam-
room air
S T E A M R O O M I N T E R I O R