background image

FED ALL

FED ALL

FED ALL

POST SB 31-2059 for A/C 413-414

 

NOTE : Setting the A/C to simulated FLT CONFIG (Ref. 32-00-00, P. Block 501),

 

the ECAM SMOKE warning will include LAND ASAP for second priority

 

of the advisory.

 

1. On COMPT TEMP panel 437VU:              On R ECAM display - AIR COND page:

 

- rotate BULK CARGO (FWD CARGO)         - hot trim air valve opens and

 

temp selector switch 14HN               remains stationary, color: green.

 

(53HN) to MAN-HOT position,

 

hold until hot trim air

 

valve flap position arrow,

 

on R ECAM display - AIR COND

 

page, is at least half opened,

 

then release selector switch.

 

2. On maintenance panel 471VU:             On maintenance panel 471VU:

 

- rotate ELEC COMPT & CARGO             - PTT pushbutton switch 52WA TEST

 

COMPT selector switch                   legend comes on.

 

16WA to CARGO COMPT/BULK/1

 

(CARGO COMPT/FWD/1) position.

 

- press and hold PTT pushbutton         On CARGO COMPT SMOKE DET panel 433VU,

 

switch 52WA.                          after 2-3 second delay:

 

A310-200 AMM - CARGO COMPARTMENT
TEMPERATURE CONTROL - ADJUSTMENT/TEST

Revision 32.0

P.Blk EFFECTIVITY: FED ALL

21-64-00-05

Printed - Date: 12/11/12 Time:
Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 94 of 106

JUN 01/2012

Summary of Contents for A310-200 AMM

Page 1: ...00 P Block 301 Ref 33 17 00 P Block 501 Ref 31 51 00 P Block 201 AC External Power Control Memorized Fault Annunciators ECAM Sxstem FED 401 405 407 414 423 430 443 445 POST SB 31 2059 for A C 401 405 407 414 423 430 443 445 Referenced Procedures Ref 24 41 00 P Block 301 Ref 32 00 00 P Block 501 Ref 33 17 00 P Block 501 Ref 31 51 00 P Block 201 AC External Power Control Landing Gear General Memoriz...

Page 2: ...26 203 G28 FED 423 430 443 445 450 22VU 22VU 22VU 22VU 22VU 22VU CARGO SMOKE DET WARN CARGO SMOKE DET PWR SUPPLY AVIONICS SMOKE DET DETECTORS AVIONICS SMOKE DET DETECTORS COMPT TEMP CARGO ISOL VALVES FWD COMPT TEMP CARGO ISOL VALVES BULK 46WH 35WH 1WA 2WA 40HN 2HN 209 A25 209 A26 204 F25 204 F26 203 G27 203 G28 FED 401 405 407 414 431 436 451 452 22VU 22VU 22VU 22VU AVIONICS SMOKE DET DETECTORS AV...

Page 3: ... H64 503 H65 503 H66 502 J64 FED 416 422 453 499 129VU 129VU 129VU 129VU 129VU 129VU LIGHTING MAINT PANEL ANN MFA LIGHTING MAINT PANEL ANN MFA LIGHTING INT LT ANN LT TEST MAN LIGHTING INT LT ANN LT TEST MAN LIGHTING INT LT ANN LT TEST MAN LIGHTING INT LT ANN LT TEST AUTO 1WB 22WB 149LP 2LP 1LP 153LP 903 S90 903 S91 902 T88 902 T89 902 T90 902 T91 FED 401 405 407 414 423 436 443 445 452 129VU 129VU...

Page 4: ...s apply for both FWD and BULK cargo compartments Component FINs for FWD compartment are shown in brackets a Test operation of BULK FWD cargo compartment isolation valve 19HN 60HN extraction fan 30HN 48HN and FANS MONITOR MFA 8HN 57HN 1 Initial conditions On COMPT TEMP panel 437VU BULK CARGO FWD CARGO temperature selector switch 14HN 53HN is in MAN position BULK CARGO ISOL VALVE FWD CARGO ISOL VALV...

Page 5: ...en On maintenance panel 472VU check that BULK CARGO MFA does not come on rotate and hold BULK CARGO temp On R ECAM display AIR COND page selector switch 14HN in MAN HOT trim air valve flap position arrow position until trim air valve flap remains stationary position arrow on R ECAM display AIR COND page is between H and C A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision ...

Page 6: ...437VU release BULK CARGO ISOL VALVE OFF R legend comes on pushbutton switch 6HN for duration of isolation valve flap movement ISOL VALVE push button switch FAULT legend comes on and then goes off On R ECAM display AIR COND page isolation valve closed isolation valve color amber On maintenance panel 472VU check that BULK CARGO MFA does not come on A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ...

Page 7: ...BULK CARGO FWD CARGO MFA does not come on rotate and hold BULK CARGO On R ECAM display AIR COND page FWD CARGO temperature selector trim air valve flap position arrow switch 14HN 53HN in MAN HOT remains stationary position until trim air valve flap position arrow on R ECAM display AIR COND page is be tween H and C then release selector switch 2 On circuit breaker panel 125VU A310 200 AMM CARGO COM...

Page 8: ...OMPT TEMP panel 437VU release BULK CARGO ISOL VALVE OFF R legend comes on FWD CARGO ISOL VALVE push for duration of isolation valve button switch 6HN 52HN flap movement ISOL VALVE push button switch FAULT legend comes on and then goes off On R ECAM display AIR COND page isolation valve closed isolation valve color amber On maintenance panel 472VU A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ...

Page 9: ...n switch 4HJ is pressed in 2 Perform test ACTION RESULT 1 At rack 91VU on APU and pack temp On APU and pack temp demand demand controller 37HK controller 37HK check that electrical power is light comes on when pressed available at APU and pack temp demand controller by pressing BITE READY UNPLUG CABLE AFTER USE light make certain that BITE SWITCH is in position 1 2 On circuit breaker panel 125VU a...

Page 10: ...re control system NOTE Position 1 Sum of outputs of pack scaling amplifiers is checked Position 2 APU speed demand signal for maximum cooling is checked Position 3 APU speed demand signal for maximum heating is checked Position 4 Bridge power supply is checked Position 5 Amplifier output is checked Position 6 Drives actuator in more heat direction Position 7 Overrides bridge output with signal to ...

Page 11: ...is located in avionics compartment at equipment rack 91VU 1 Initial conditions On COMPT TEMP panel 437VU PACK VALVE 1 and 2 pushbutton switches 191HB and 189HB are pressed in BULK CARGO ISOL VALVE FWD CARGO ISOL VALVE pushbutton switch 6HN 52HN is pressed in BULK CARGO FWD CARGO temperature selector switch 14HN 53HN is in AUTO position HOT AIR SUPPLY pushbutton switch 4HJ is pressed in 2 Perform t...

Page 12: ...ck temp demand controller at location H65 close circuit BITE READY UNPLUG CABLE AFTER breaker 5HN USE and GO indicator lights come at location H63 close circuit on breaker 43HN 5 On APU and pack temperature demand controller press NO GO indicator light NO GO integral light comes on place BITE SWITCH to positions for each position selected 1 thru 12 in sequence pausing GO indicator light must come ...

Page 13: ...cked Position 11 Output of bridge is checked Position 12 Selector output signal is checked return BITE SWITCH to position 1 6 On circuit breaker panel 125VU On APU and pack temperature demand controller at location H65 open circuit BITE READY UNPLUG CABLE AFTER breaker 5HN USE and GO indicator lights go off at location H63 open circuit breaker 43HN 7 On BULK CARGO FWD CARGO compt temp controller d...

Page 14: ...orm test ACTION RESULT 1 At rack 91VU on APU and pack temp On APU and pack temp demand demand controller 37HK controller 37HK check that electrical power is light comes on when pressed available at APU and pack temp demand controller by pressing BITE READY UNPLUG CABLE AFTER USE light make certain that BITE SWITCH is in position 1 2 On circuit breaker panel 125VU at location H65 open circuit break...

Page 15: ...ws a failure in the cargo compartment temperature control system NOTE Position 1 Sum of outputs of pack scaling amplifiers is checked Position 2 APU speed demand signal for maximum cooling is checked Position 3 APU speed demand signal for maximum heating is checked Position 4 Bridge power supply is checked Position 5 Amplifier output is checked Position 6 Drives actuator in more heat direction Pos...

Page 16: ...5VU at location H65 close circuit breaker 5HN at location H63 close circuit breaker 43HN c Test operation of cold trim air valve 81HN 69HN 1 Initial conditions ON COMPT TEMP panel 437VU BULK CARGO FWD CARGO temperature selector switch 14HN 53HN is in MAN position BULK CARGO ISOL VALVE FWD CARGO ISOL VALVE pushbutton switch 6HN 52HN is pressed in 2 Perform test ACTION RESULT 1 On COMPT TEMP panel 4...

Page 17: ...ition FWD CARGO temp selector arrow moves to C then cold trim switch 14HN 53HN in air valve flap position arrow MAN COLD position moves to open position release BULK CARGO FWD CARGO both trim air valve flap position temp selector switch 14HN 53HN arrows remain stationary 4 On CARGO COOL panel 444VU On CARGO COOL panel 444VU release BULK FWD pushbutton ON legend goes off switch 80HN 78HN On L ECAM ...

Page 18: ...20HN and extraction fan 30HN when SMOKE warning is simulated 1 Initial conditions On COMPT TEMP panel 437VU BULK CARGO temperature selector switch 14HN is in MAN position BULK CARGO ISOL VALVE pushbutton switch 6HN is pressed in On maintenance panel 472VU ANN LT toggle switch 2WB is in READ position 2 Perform test c FED 421 422 453 499 Test operation of BULK cargo compartment isolation valve 19HN ...

Page 19: ...VALVE pushbutton switch 6HN 52HN is pressed in On maintenance panel 472VU ANN LT toggle switch 2WB is in READ position 2 Perform test FED 401 405 407 414 d Test operation of BULK FWD cargo compartment isolation valve 19HN 60HN hot trim air valve 20HN 61HN cold trim air valve 81HN 69HN and extraction fan 30HN 48HN when SMOKE warning is simulated 1 Initial conditions On COMPT TEMP panel 437VU BULK C...

Page 20: ...in On maintenance panel 472VU ANN LT toggle switch 2WB is in READ position On CARGO COMPT SMOKE DET panel 433VU FWD LOOP A 21WH FWD LOOP B 22WH AFT LOOP A 23WH AFT LOOP B 24WH BULK LOOP A 25WH and BULK LOOP B 26WH pushbutton switches are pressed in 2 Perform test FED 453 499 ACTION RESULT 1 On CARGO COMPT SMOKE On CARGO COMPT SMOKE DET panel 433VU DET panel 433VU release BULK LOOP B push OFF legen...

Page 21: ...on R ECAM display AIR COND page is at H then release selector switch 3 On maintenance panel 471VU On maintenance panel 471VU rotate ELEC COMPT CARGO COMPT TEST legend off PTT pushbutton selector switch 16WA to CARGO switch 52WA comes on COMPT BULK position place CARGO COMPT LOOP TEST SEL toggle switch 48WH to LOOP A position A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revisi...

Page 22: ...isplay AIR COND page isolation valve closes and color changes to amber trim air valve flap position arrow moves to position C On L ECAM display SMOKE BULK CARGO COMPT SMOKE AGENT 1 DISCH LDG ELEVATION 10 000 FT MAX FL 100 MEA appears release PTT pushbutton switch On CARGO COMPT SMOKE DET panel 433VU A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY ...

Page 23: ...VU reset BULK CARGO ISOL VALVE after isolation valve opens pushbutton switch 6HN ISOL VALVE pushbutton switch FAULT legend goes off On R ECAM display AIR COND page isolation valve opens and color changes to green trim air valve flap position arrow A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time Copyri...

Page 24: ... DET panel panel 433VU 433VU press BULK LOOP B pushbutton OFF legend goes off switch 26WH On WLDP LOOP warning light goes off On L ECAM display LOOP BULK COMPT LOOP B OFF disappears FED 453 454 456 499 A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time Copyright 12 FedEx Express Corporation Memphis TN 38...

Page 25: ...ector switch 14HN in position arrow remains stationary MAN HOT position until trim at H air valve flap position arrow on R ECAM display AIR COND page is at H then release selector switch 3 On maintenance panel 471VU On maintenance panel 471VU rotate ELEC COMPT CARGO COMPT TEST legend off PTT pushbutton selector switch 16WA to CARGO switch 52WA comes on A310 200 AMM CARGO COMPARTMENT TEMPERATURE CO...

Page 26: ...t repetitive chime sounds On COMPT TEMP panel 437VU BULK CARGO ISOL VALVE pushbutton switch 6HN FAULT legend comes on On R ECAM display AIR COND page isolation valve closes and color changes to amber trim air valve flap position arrow moves to position C On L ECAM display A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed ...

Page 27: ...hime stops On L ECAM display SMOKE BULK CARGO COMPT SMOKE AGENT 1 DISCH LDG ELEVATION 10 000 FT MAX FL 100 MEA disappears 5 On COMPT TEMP panel 437VU On COMPT TEMP panel 437VU reset BULK CARGO ISOL VALVE after isolation valve opens A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time Copyright 12 FedEx Exp...

Page 28: ... On CARGO COMPT SMOKE DET On CARGO COMPT SMOKE DET panel panel 433VU 433VU press BULK LOOP B pushbutton OFF legend goes off switch 26WH On WLDP LOOP warning light goes off On L ECAM display LOOP BULK COMPT LOOP B OFF disappears FED 416 436 443 445 451 499 POST SB 31 2035 for A C 423 435 443 445 453 499 POST SB 31 2059 for A C 423 430 443 445 A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUS...

Page 29: ...on In flight compartment single chime sounds On L ECAM display LOOP BULK COMPT LOOP B OFF FWD COMPT LOOP B OFF appears 2 On COMPT TEMP panel 437VU On R ECAM display AIR COND page rotate BULK CARGO FWD CARGO hot trim air valve opens and temp selector switch 14HN remains stationary color green A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL ...

Page 30: ...lace CARGO COMPT LOOP TEST SEL toggle switch 48WH to LOOP A position 4 On maintenance panel 471VU On CARGO COMPT SMOKE DET panel 433VU press and hold PTT push BULK SMOKE FWD SMOKE red button switch 52WA warning light 12WH 1WH and LOOP A 25WH 21WH legend come on On WLDP SMOKE warning light flashes In flight compartment A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0...

Page 31: ...n L ECAM display SMOKE BULK CARGO COMPT SMOKE FWD CARGO COMPT SMOKE LDG ELEVATION 10 000 FT appears release PTT pushbutton switch On CARGO COMPT SMOKE DET panel 433VU BULK SMOKE FWD SMOKE red warning light and LOOP A legend go off On WLDP A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time Copyright 12 Fe...

Page 32: ...itch legend goes off 6HN 52HN On R ECAM display AIR COND page isolation valve opens and color changes to green hot trim air valve flap position arrow remains at position C 6 On CARGO COOL panel 444VU On CARGO COOL panel 444VU press BULK FWD pushbutton switch ON legend comes on 80HN 78HN On L ECAM display MEMO A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EF...

Page 33: ...air valve flap CARGO temp selector switch position arrow remains 14HN 53HN when cold trim stationary air valve is approx half opened 8 On maintenance panel 471VU On CARGO COMPT SMOKE DET panel 433VU press and hold PTT push BULK SMOKE FWD SMOKE red button switch 52WA warning light 12WH 1WH and LOOP A legend 25WH 21WH come on On WLDP SMOKE warning light flashes A310 200 AMM CARGO COMPARTMENT TEMPERA...

Page 34: ...ock closed position On L ECAM display SMOKE BULK CARGO COMPT SMOKE FWD CARGO COMPT SMOKE LDG ELEVATION 10 000 FT appears release PTT pushbutton On CARGO COMPT SMOKE DET panel 433VU switch BULK SMOKE FWD SMOKE warning light and LOOP A legend go off On WLDP A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Tim...

Page 35: ...nd goes off On R ECAM display AIR COND page isolation valve opens and color changes to green cold trim air valve flap position arrow remains at 10 o clock closed position 10 On maintenance panel 471VU On maintenance panel 471VU rotate ELEC COMPT CARGO TEST legend of PTT pushbutton COMPT selector switch 16WA switch 52WA goes off A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Rev...

Page 36: ...n CARGO COOL panel 444VU release BULK FWD pushbutton ON legend goes off switch 80HN 78HN On L ECAM display BULK CARGO COOLING ON FWD CARGO COOLING ON disappears On R ECAM display AIR COND page cold trim air valve flap position arrow and scale disappear Before SB 31 2035 A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Da...

Page 37: ... COMPT TEMP panel 437VU On R ECAM display AIR COND page rotate BULK CARGO FWD CARGO hot trim air valve opens and temp selector switch 14HN remains stationary color green 53HN to MAN HOT position hold until hot trim air valve flap position arrow on R ECAM display AIR COND page is at least half opened A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY ...

Page 38: ...ess and hold PTT push BULK SMOKE FWD SMOKE red button switch 52WA warning light 12WH 1WH and LOOP A 25WH 21WH legend come on On WLDP SMOKE warning light flashes In flight compartment repetitive chime sounds On COMPT TEMP panel 437VU BULK CARGO ISOL VALVE FWD CARGO ISOL VALVE push button switch 6HN 52HN FAULT legend comes on A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revisio...

Page 39: ... pushbutton switch On CARGO COMPT SMOKE DET panel 433VU BULK SMOKE FWD SMOKE red warning light and LOOP A legend go off On WLDP SMOKE warning light goes off In flight compartment repetitive chime stops On L ECAM display A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time Copyright 12 FedEx Express Corpora...

Page 40: ...lation valve opens and color changes to green hot trim air valve flap position arrow remains at position C 6 On CARGO COOL panel 444VU On CARGO COOL panel 444VU press BULK FWD pushbutton switch ON legend comes on 80HN 78HN On L ECAM display MEMO BULK CARGO COOLING ON FWD CARGO COOLING ON appears A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ...

Page 41: ...n cold trim stationary air valve is approx half opened 8 On maintenance panel 471VU On CARGO COMPT SMOKE DET panel 433VU press and hold PTT push BULK SMOKE FWD SMOKE red button switch 52WA warning light 12WH 1WH and LOOP A legend 25WH 21WH come on On WLDP SMOKE warning light flashes In flight compartment repetitive chime sounds On COMPT TEMP panel 437VU BULK CARGO ISOL VALVE FWD CARGO A310 200 AMM...

Page 42: ...OKE AGENT 1 DISCH LDG ELEVATION 10 000 FT appears release PTT pushbutton On CARGO COMPT SMOKE DET panel 433VU switch BULK SMOKE FWD SMOKE warning light and LOOP A legend go off On WLDP SMOKE warning light goes off In flight compartment A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time Copyright 12 FedEx...

Page 43: ... AIR COND page isolation valve opens and color changes to green cold trim air valve flap position arrow remains at 10 o clock closed position 10 On maintenance panel 471VU On maintenance panel 471VU rotate ELEC COMPT CARGO TEST legend of PTT pushbutton COMPT selector switch 16WA switch 52WA goes off to NORM FLT position A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32...

Page 44: ...play BULK CARGO COOLING ON FWD CARGO COOLING ON disappears On R ECAM display AIR COND page cold trim air valve flap position arrow and scale disappear FED 423 430 443 445 PRE SB 21 2015 for A C 423 430 443 445 PRE SB 31 2023 for A C 423 430 443 445 PRE SB 31 2035 for A C 423 430 443 445 1 On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTR...

Page 45: ...lector switch 14HN remains stationary color green 53HN to MAN HOT position hold until hot trim air valve flap position arrow on R ECAM display AIR COND page is at least half opened then release selector switch 3 On maintenance panel 471VU On maintenance panel 471VU rotate ELEC COMPT CARGO TEST legend of PTT pushbutton A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0...

Page 46: ...5WH 21WH legend come on On WLDP SMOKE warning light flashes In flight compartment repetitive chime sounds On COMPT TEMP panel 437VU for duration of isolation valve flap movement BULK CARGO ISOL VALVE FWD CARGO ISOL VALVE pushbutton switch 6HN 52HN FAULT legend comes on and then goes off A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64...

Page 47: ...U BULK CARGO FWD CARGO MFA 8HN 57HN comes on release PTT pushbutton switch On CARGO COMPT SMOKE DET panel 433VU BULK SMOKE FWD SMOKE red warning light and LOOP A legend go off On WLDP SMOKE warning light goes off In flight compartment A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time Copyright 12 FedEx ...

Page 48: ...FAULT legend comes on 6HN 52HN and then goes off On R ECAM display AIR COND page isolation valve opens and color changes to green hot trim air valve flap position arrow remains at position C On maintenance panel 472VU BULK CARGO FWD CARGO MFA 8HN 57HN remains on 6 On maintenance panel 472VU A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 2...

Page 49: ...37VU rotate to and hold BULK hot trim air valve flap position CARGO FWD CARGO temp arrow remains at C and cold selector switch 14HN trim air valve flap position 53HN in MAN COLD posi arrow moves to position C tion release BULK CARGO FWD cold trim air valve flap CARGO temp selector switch position arrow remains 14HN 53HN when cold trim stationary A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL A...

Page 50: ...f isolation valve flap movement BULK CARGO ISOL VALVE FWD CARGO ISOL VALVE pushbutton switch 6HN 52HN FAULT legend comes on and then goes off On R ECAM display AIR COND page isolation valve closes and color changes to amber cold trim air valve flap position arrow moves to 10 o clock closed position A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY F...

Page 51: ... FWD SMOKE warning light and LOOP A legend go off On WLDP SMOKE warning light goes off In flight compartment repetitive chime stops On L ECAM display SMOKE BULK CARGO COMPT SMOKE FWD CARGO COMPT SMOKE AGENT 1 DISCH A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time Copyright 12 FedEx Express Corporation ...

Page 52: ... position 11 On maintenance panel 472VU On maintenance panel 472VU press MFA RESET push BULK CARGO FWD CARGO MFA button switch 20WB goes off 12 On maintenance panel 471VU On maintenance panel 471VU rotate ELEC COMPT CARGO TEST legend of PTT pushbutton COMPT selector switch 16WA switch 52WA goes off to NORM FLT position 13 On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel A310 200 AMM C...

Page 53: ...NG ON FWD CARGO COOLING ON disappears On R ECAM display AIR COND page cold trim air valve flap position arrow and scale disappear Before SB 21 2015 Post SB 31 2023 For A C 001 009 501 501 551 551 Post SB 31 2035 For A C 001 009 501 501 551 551 1 On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFEC...

Page 54: ...lector switch 14HN remains stationary color green 53HN to MAN HOT position hold until hot trim air valve flap position arrow on R ECAM display AIR COND page is at least half opened then release selector switch 3 On maintenance panel 471VU On maintenance panel 471VU rotate ELEC COMPT CARGO TEST legend of PTT pushbutton A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0...

Page 55: ...A 25WH 21WH legend come on On WLDP SMOKE warning light flashes In flight compartment repetitive chime sounds On COMPT TEMP panel 437VU for duration of isolation valve flap movement BULK CARGO ISOL VALVE FWD CARGO ISOL VALVE pushbutton switch 6HN 52HN legend comes on and then goes off A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00...

Page 56: ...RGO MFA 8HN 57HN comes on release PTT pushbutton switch On CARGO COMPT SMOKE DET panel 433VU BULK SMOKE FWD SMOKE red warning light and LOOP A legend go off On WLDP SMOKE warning light goes off In flight compartment repetitive chime stops A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time Copyright 12 Fe...

Page 57: ...lay AIR COND page isolation valve opens and color changes to green hot trim air valve flap position arrow remains at position C On maintenance panel 472VU BULK CARGO FWD CARGO MFA 8HN 57HN remains on 6 On maintenance panel 472VU press MFA RESET pushbutton BULK CARGO FWD CARGO MFA goes switch 20WB off and remains off A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P...

Page 58: ...ns at C and cold selector switch 14HN trim air valve flap position 53HN in MAN COLD posi arrow moves to position C tion release BULK CARGO FWD cold trim air valve flap CARGO temp selector switch position arrow remains 14HN 53HN when cold trim stationary air valve is approx half opened 9 On maintenance panel 471VU On CARGO COMPT SMOKE DET panel 433VU A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTR...

Page 59: ...RGO ISOL VALVE pushbutton switch 6HN 52HN FAULT legend comes on and then goes off On R ECAM display AIR COND page isolation valve closes and color changes to amber cold trim air valve flap position arrow moves to 10 o clock closed position On L ECAM display SMOKE A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 1...

Page 60: ...In flight compartment repetitive chime stops On L ECAM display SMOKE BULK CARGO COMPT SMOKE FWD CARGO COMPT SMOKE LDG ELEVATION 10 000 FT disappears 10 On COMPT TEMP panel 437VU On COMPT TEMP panel 437VU reset BULK CARGO ISOL VALVE for duration of isolation valve A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 1...

Page 61: ...intenance panel 472VU press MFA RESET push BULK CARGO FWD CARGO MFA button switch 20WB goes off 12 On maintenance panel 471VU On maintenance panel 471VU rotate ELEC COMPT CARGO TEST legend of PTT pushbutton COMPT selector switch 16WA switch 52WA goes off to NORM FLT position 13 On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel 433VU 433VU A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONT...

Page 62: ...NG ON FWD CARGO COOLING ON disappears On R ECAM display AIR COND page cold trim air valve flap position arrow and scale disappear Before SB 31 2023 Before SB 31 2035 Post SB 21 2015 For A C 001 001 003 003 008 009 551 551 1 On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel 433VU 433VU A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED...

Page 63: ...ationary color green 53HN to MAN HOT position hold until hot trim air valve flap position arrow on R ECAM display AIR COND page is at least half opened then release selector switch 3 On maintenance panel 471VU On maintenance panel 471VU rotate ELEC COMPT CARGO TEST legend of PTT pushbutton COMPT selector switch 16WA switch 52WA comes on A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT...

Page 64: ...OKE warning light flashes In flight compartment repetitive chime sounds On COMPT TEMP panel 437VU BULK CARGO ISOL VALVE FWD CARGO ISOL VALVE push button switch 6HN 52HN FAULT legend comes on On R ECAM display AIR COND page isolation valve closes and color changes to amber A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed ...

Page 65: ...OKE red warning light and LOOP A legend go off On WLDP SMOKE warning light goes off In flight compartment repetitive chime stops On L ECAM display SMOKE BULK CARGO COMPT SMOKE FWD CARGO COMPT SMOKE AGENT 1 DISCH A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time Copyright 12 FedEx Express Corporation Mem...

Page 66: ...s at position C 6 On CARGO COOL panel 444VU On CARGO COOL panel 444VU press BULK FWD pushbutton switch ON legend comes on 8OHN 78HN On L ECAM display MEMO BULK CARGO COOLING ON FWD CARGO COOLING ON appears On R ECAM display AIR COND page cold trim air valve flap position arrow with scale appears 7 On COMPT TEMP panel 437VU A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision...

Page 67: ...DET panel 433VU press and hold PTT push BULK SMOKE FWD SMOKE red button switch 52WA warning light 12WH 1WH and LOOP A legend 25WH 21WH come on On WLDP SMOKE warning light flashes In flight compartment repetitive chime sounds On COMPT TEMP panel 437VU BULK CARGO ISOL VALVE FWD CARGO ISOL VALVE pushbutton switch 6HN 52HN FAULT legend comes on On R ECAM display AIR COND page A310 200 AMM CARGO COMPAR...

Page 68: ...O COMPT SMOKE DET panel 433VU switch BULK SMOKE FWD SMOKE warning light and LOOP A legend go off On WLDP SMOKE warning light goes off In flight compartment repetitive chime stops On L ECAM display SMOKE BULK CARGO COMPT SMOKE A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time Copyright 12 FedEx Express C...

Page 69: ... at 10 o clock closed position 10 On maintenance panel 471VU On maintenance panel 471VU rotate ELEC COMPT CARGO TEST legend of PTT pushbutton COMPT selector switch 16WA switch 52WA goes off to NORM FLT position 11 On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel 433VU 433VU press BULK LOOP B FWD OFF legend goes off LOOP B pushbutton switch On WLDP A310 200 AMM CARGO COMPARTMENT TEMPER...

Page 70: ...d trim air valve flap position arrow and scale disappear FED 446 450 POST SB 31 2035 for A C 446 450 1 On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel 433VU 433VU release BULK LOOP B FWD LOOP B OFF legend comes on pushbutton switch 26WH 22WH On main instrument panels 3VU and 5VU A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL...

Page 71: ...air valve flap position arrow on R ECAM display AIR COND page is at least half opened then release selector switch 3 On maintenance panel 471VU On maintenance panel 471VU rotate ELEC COMPT CARGO TEST legend of PTT pushbutton COMPT selector switch 16WA switch 52WA comes on to CARGO COMPT BULK CARGO COMPT FWD 1 position A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0...

Page 72: ...ompartment repetitive chime sounds On COMPT TEMP panel 437VU BULK CARGO ISOL VALVE FWD CARGO ISOL VALVE pushbutton switch 6HN 52HN FAULT legend comes on On R ECAM display AIR COND page isolation valve closes and color changes to amber hot trim air valve flap position arrow moves to position C A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL...

Page 73: ...ent panels 3VU and 5VU MASTER WARNING lights go off In flight compartment repetitive chime stops On L ECAM display SMOKE BULK CARGO COMPT SMOKE FWD CARGO COMPT SMOKE LDG ELEVATION 10 000 FT disappears A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time Copyright 12 FedEx Express Corporation Memphis TN 381...

Page 74: ...s BULK FWD pushbutton switch ON legend comes on 80HN 78HN On L ECAM display MEMO BULK CARGO COOLING ON FWD CARGO COOLING ON appears On R ECAM display AIR COND page cold trim air valve flap position arrow with scale appears 7 On COMPT TEMP panel 437VU rotate and hold BULK CARGO hot trim air valve flap position FWD CARGO temp selector arrow remains at C and cold A310 200 AMM CARGO COMPARTMENT TEMPER...

Page 75: ...52WA light 12WH 1WH and LOOP A legend 25WH 21WH come on On main instrument panels 3VU and 5VU MASTER WARNING lights flash In flight compartment repetitive chime sounds On COMPT TEMP panel 437VU BULK CARGO ISOL VALVE FWD CARGO ISOL VALVE pushbutton switch 6HN 52HN FAULT legend comes on On R ECAM display AIR COND page isolation valve closes and A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJU...

Page 76: ... BULK SMOKE FWD SMOKE warning light and LOOP A legend go off On main instrument panels 3VU and 5VU MASTER WARNING lights go off In flight compartment repetitive chime stops On L ECAM display SMOKE BULK CARGO COMPT SMOKE A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time Copyright 12 FedEx Express Corpora...

Page 77: ...ion 10 On maintenance panel 471VU On maintenance panel 471VU rotate ELEC COMPT CARGO TEST legend of PTT pushbutton COMPT selector switch 16WA switch 52WA goes off to NORM FLT position 11 On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel 433VU 433VU press BULK LOOP B FWD OFF legend goes off LOOP B pushbutton switch On main instrument panels 3VU 26WH 22WH and 5VU A310 200 AMM CARGO COMPA...

Page 78: ...ap position arrow and scale disappear FED 447 449 POST SB 31 2035 for A C 447 449 1 On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel 433VU 433VU release BULK LOOP B FWD LOOP B OFF legend comes on pushbutton switch 26WH 22WH On main instrument panels 3VU and 5VU MASTER CAUTION lights come on A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIV...

Page 79: ...osition arrow on R ECAM display AIR COND page is at least half opened then release selector switch 3 On maintenance panel 471VU On maintenance panel 471VU rotate ELEC COMPT CARGO TEST legend of PTT pushbutton COMPT selector switch 16WA switch 52WA comes on to CARGO COMPT BULK CARGO COMPT FWD 1 position A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVI...

Page 80: ...ompartment repetitive chime sounds On COMPT TEMP panel 437VU BULK CARGO ISOL VALVE FWD CARGO ISOL VALVE pushbutton switch 6HN 52HN FAULT legend comes on On R ECAM display AIR COND page isolation valve closes and color changes to amber hot trim air valve flap position arrow moves to position C A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL...

Page 81: ...ER WARNING lights go off In flight compartment repetitive chime stops On L ECAM display SMOKE BULK CARGO COMPT SMOKE FWD CARGO COMPT SMOKE LDG ELEVATION 10 000 FT disappears 5 On COMPT TEMP panel 437VU On COMPT TEMP panel 437VU A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time Copyright 12 FedEx Express...

Page 82: ...h ON legend comes on 80HN 78HN On L ECAM display MEMO BULK CARGO COOLING ON FWD CARGO COOLING ON appears On R ECAM display AIR COND page cold trim air valve flap position arrow with scale appears 7 On COMPT TEMP panel 437VU rotate and hold BULK CARGO hot trim air valve flap position FWD CARGO temp selector arrow remains at C and cold A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TE...

Page 83: ...52WA light 12WH 1WH and LOOP A legend 25WH 21WH come on On main instrument panels 3VU and 5VU MASTER WARNING lights flash In flight compartment repetitive chime sounds On COMPT TEMP panel 437VU BULK CARGO ISOL VALVE FWD CARGO ISOL VALVE pushbutton switch 6HN 52HN FAULT legend comes on On R ECAM display AIR COND page isolation valve closes and A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJU...

Page 84: ... FWD SMOKE warning light and LOOP A legend go off On main instrument panels 3VU and 5VU MASTER WARNING lights go off In flight compartment repetitive chime stops On L ECAM display SMOKE BULK CARGO COMPT SMOKE FWD CARGO COMPT SMOKE A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time Copyright 12 FedEx Expr...

Page 85: ...aintenance panel 471VU On maintenance panel 471VU rotate ELEC COMPT CARGO TEST legend of PTT pushbutton COMPT selector switch 16WA switch 52WA goes off to NORM FLT position 11 On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel 433VU 433VU press BULK LOOP B FWD OFF legend goes off LOOP B pushbutton switch On main instrument panels 3VU 26WH 22WH and 5VU A310 200 AMM CARGO COMPARTMENT TEMP...

Page 86: ...AIR COND page cold trim air valve flap position arrow and scale disappear FED 401 405 407 412 POST SB 31 2059 for A C 401 405 407 412 NOTE Setting the A C to simulated FLT CONFIG Ref 32 00 00 P Block 501 the ECAM SMOKE warning will include LAND ASAP for second priority A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Dat...

Page 87: ...el 471VU rotate ELEC COMPT CARGO PTT pushbutton switch 52WA TEST COMPT selector switch 16WA legend comes on to CARGO COMPT BULK 1 CARGO COMPT FWD 1 position press and hold PTT pushbutton On CARGO COMPT SMOKE DET panel 433VU switch 52WA after approx 2 3 second delay AFT BULK SMOKE FWD SMOKE red warning light 38WH 39WH comes on In flight compartment A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL...

Page 88: ...es to position C On L ECAM display SMOKE AFT BULK CARGO COMPT SMOKE FWD CARGO COMPT SMOKE LDG ELEVATION 10 000 FT MAX FL 100 MEA appears release PTT pushbutton On CARGO COMPT SMOKE DET panel 433VU switch AFT BULK SMOKE FWD SMOKE red warning light goes off A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Tim...

Page 89: ... switch FAULT VALVE pushbutton switch legend goes off 6HN 52HN On R ECAM display AIR COND page isolation valve opens and color changes to green hot trim air valve flap position arrow remains at position C 4 On CARGO COOL panel 444VU On CARGO COOL panel 444VU press BULK FWD pushbutton ON legend comes on A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVI...

Page 90: ...ap position position arrow moves towards position C release BULK CARGO FWD CARGO cold trim air valve flap temp selector switch 14HN position arrow remains stationary 53HN when cold trim air valve 81HN 69HN is approx half open 6 On maintenance panel 471VU On CARGO COMPT SMOKE DET panel 433VU press and hold PTT pushbutton after approx 2 3 second delay A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTR...

Page 91: ...play AIR COND page isolation valve closes and color changes to amber cold trim air valve flap position arrow moves to 10 o clock closed position On L ECAM display SMOKE AFT BULK CARGO COMPT SMOKE FWD CARGO COMPT SMOKE LDG ELEVATION 10 000 FT A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time Copyright 12...

Page 92: ...MEA disappears 7 On COMPT TEMP panel 437VU On COMPT TEMP panel 437VU reset BULK CARGO ISOL VALVE after isolation valve opens FWD CARGO ISOL VALVE ISOL VALVE pushbutton switch FAULT pushbutton switch 6HN legend goes off 52HN On R ECAM display AIR COND page isolation valve opens and A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05...

Page 93: ...ay AIR COND page cold trim air valve flap position arrow and scale disappear 9 On maintenance panel 471VU On maintenance panel 471VU rotate ELEC COMPT CARGO PTT pushbutton switch 52WA TEST COMPT selector switch 16WA legend goes off to NORM FLT position FED 413 414 A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 ...

Page 94: ... R ECAM display AIR COND page is at least half opened then release selector switch 2 On maintenance panel 471VU On maintenance panel 471VU rotate ELEC COMPT CARGO PTT pushbutton switch 52WA TEST COMPT selector switch legend comes on 16WA to CARGO COMPT BULK 1 CARGO COMPT FWD 1 position press and hold PTT pushbutton On CARGO COMPT SMOKE DET panel 433VU switch 52WA after 2 3 second delay A310 200 AM...

Page 95: ...L VALVE FWD CARGO ISOL VALVE pushbutton switch 6HN 52HN FAULT legend comes on and then goes off On R ECAM display AIR COND page isolation valve closes and color changes to amber hot trim air valve flap position arrow moves to position C On L ECAM display A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time...

Page 96: ...e stops On L ECAM display SMOKE AFT BULK CARGO COMPT SMOKE FWD CARGO COMPT SMOKE LDG ELEVATION 10 000 FT MAX FL 100 MEA disappears 3 On COMPT TEMP panel 437VU On COMPT TEMP panel 437VU reset BULK CARGO ISOL VALVE for duration of isolation valve A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time Copyright...

Page 97: ...tion C 4 On maintenance panel 472VU On maintenance panel 472VU press MFA RESET pushbutton BULK CARGO FWD CARGO MFA switch 20WB goes off 5 On CARGO COOL panel 444VU On CARGO COOL panel 444VU press BULK FWD pushbutton ON legend comes on switch 8OHN 78HN On L ECAM display MEMO BULK CARGO COOLING ON FWD CARGO COOLING ON appears A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revisio...

Page 98: ... position arrow remains 14HN 53HN when cold trim stationary air valve is approx half open 7 On maintenance panel 471VU On CARGO COMPT SMOKE DET panel 433VU press and hold PTT pushbutton after approx 2 3 second delay switch 52WA AFT BULK SMOKE FWD SMOKE red warning light 38WH 39WH comes on In flight compartment repetitive chime sounds On WLDP SMOKE warning light flashes On COMPT TEMP panel 437VU A3...

Page 99: ...r valve flap position arrow moves to 10 o clock closed position On L ECAM display SMOKE AFT BULK CARGO COMPT SMOKE FWD CARGO COMPT SMOKE LDG ELEVATION 10 000 FT MAX FL 100 MEA appears release PTT pushbutton On CARGO COMP SMOKE DET panel 433VU A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time Copyright 1...

Page 100: ...eset BULK CARGO ISOL VALVE for duration of isolation valve FWD CARGO ISOL VALVE flap movement ISOL VALVE push pushbutton switch 6HN 52HN button switch FAULT legend comes on and then goes off On R ECAM display AIR COND page isolation valve opens and color changes to green A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed D...

Page 101: ...M display BULK CARGO COOLING ON FWD CARGO COOLING ON disappears On R ECAM display AIR COND page cold trim air valve flap position arrow and scale disappear 11 On maintenance panel 471VU On maintenance panel 471VU rotate ELEC COMPT CARGO PTT pushbutton switch 52WA COMPT selector switch TEST legend goes off 16WA to NORM FLT position A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST ...

Page 102: ...GO trim air valve opens fully and flap temp selector switch 14HN in position arrow remains stationary MAN HOT position until trim at H air valve flap position arrow on R ECAM display AIR COND page is at H then release selector switch 3 On maintenance panel 471VU On maintenance panel 471VU rotate ELEC COMPT CARGO COMPT TEST legend off PTT pushbutton A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTRO...

Page 103: ...light flashes In flight compartment repetitive chime sounds On COMPT TEMP panel 437VU BULK CARGO ISOL VALVE pushbutton switch 6HN FAULT legend comes on On R ECAM display AIR COND page isolation valve closes and color changes to amber trim air valve flap position arrow moves to position C A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 6...

Page 104: ...CAM display SMOKE BULK CARGO COMPT SMOKE AGENT 1 DISCH LDG ELEVATION 10 000 FT disappears 5 On COMPT TEMP panel 437VU On COMPT TEMP panel 437VU reset BULK CARGO ISOL VALVE after isolation valve opens pushbutton switch 6HN ISOL VALVE pushbutton switch A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Date 12 11 12 Time Cop...

Page 105: ...WA goes off position 7 On CARGO COMPT SMOKE DET On CARGO COMPT SMOKE DET panel panel 433VU 433VU press BULK LOOP B pushbutton OFF legend goes off switch 26WH On WLDP LOOP warning light goes off On L ECAM display LOOP BULK COMPT LOOP B OFF disappears FED 416 422 453 499 A310 200 AMM CARGO COMPARTMENT TEMPERATURE CONTROL ADJUSTMENT TEST Revision 32 0 P Blk EFFECTIVITY FED ALL 21 64 00 05 Printed Dat...

Page 106: ...a On maintenance panel 472VU place ANN LT toggle switch 2WB in OFF position b On ECAM control panel release ECAM SGU 1 and 2 pushbutton switches c On COMPT TEMP panel 437VU rotate BULK CARGO FWD CARGO temperature selector switch 14HN 53HN to AUTO position d Make certain that working area is clean and clear of tools and miscellaneous items of equipment e De energize aircraft electrical network and ...