- repetitive chime stops.
On L ECAM display:
SMOKE
BULK CARGO COMPT SMOKE
(FWD CARGO COMPT SMOKE)
- AGENT 1 - DISCH
- LDG ELEVATION - 10,000 FT
disappears.
9. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:
- reset BULK CARGO/ISOL VALVE - after isolation valve opens,
(FWD CARGO/ISOL VALVE) push- ISOL VALVE pushbutton switch FAULT
button switch 6HN (52HN). legend goes off.
On R ECAM display - AIR COND page:
- isolation valve opens and
color changes to green.
- cold trim air valve flap position
arrow remains at 10 o'clock
(closed) position.
10. On maintenance panel 471VU: On maintenance panel 471VU:
- rotate ELEC COMPT & CARGO - TEST legend of PTT pushbutton
COMPT selector switch 16WA switch 52WA goes off.
to NORM/FLT position.
A310-200 AMM - CARGO COMPARTMENT
TEMPERATURE CONTROL - ADJUSTMENT/TEST
Revision 32.0
P.Blk EFFECTIVITY: FED ALL
21-64-00-05
Printed - Date: 12/11/12 Time:
Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 43 of 106
JUN 01/2012