- reset BULK CARGO/ISOL VALVE - after isolation valve opens,
(FWD CARGO/ISOL VALVE) ISOL VALVE pushbutton switch FAULT
pushbutton switch 6HN (52HN). legend goes off.
On R ECAM display - AIR COND page:
- isolation valve opens and color
changes to green.
- hot trim air valve flap position
arrow remains at position C.
6. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:
- press BULK (FWD) pushbutton switch - ON legend comes on.
80HN (78HN). On L ECAM display:
MEMO
BULK CARGO COOLING ON
(FWD CARGO COOLING ON)
appears.
On R ECAM display - AIR COND page:
- cold trim air valve flap position
arrow with scale appears.
7. On COMPT TEMP panel 437VU:
- rotate and hold BULK CARGO - hot trim air valve flap position
(FWD CARGO) temp selector arrow remains at C and cold
A310-200 AMM - CARGO COMPARTMENT
TEMPERATURE CONTROL - ADJUSTMENT/TEST
Revision 32.0
P.Blk EFFECTIVITY: FED ALL
21-64-00-05
Printed - Date: 12/11/12 Time:
Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 82 of 106
JUN 01/2012