- rotate and hold BULK - hot trim air valve flap position
CARGO (FWD CARGO) temp arrow remains at C and cold
selector switch 14HN (53HN) trim air valve flap position
in MAN-COLD position. arrow moves to position C.
- release BULK CARGO (FWD - cold trim air valve flap
CARGO) temp selector switch position arrow remains
14HN (53HN) when cold trim stationary.
air valve is approx. half opened.
8. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU:
- press and hold PTT push- - BULK/SMOKE (FWD/SMOKE) red
button switch 52WA. warning light 12WH (1WH) and LOOP A
legend 25WH (21WH) come on.
On WLDP:
- SMOKE warning light flashes.
In flight compartment:
- repetitive chime sounds.
On COMPT TEMP panel 437VU:
- BULK CARGO/ISOL VALVE (FWD CARGO/
ISOL VALVE) pushbutton switch 6HN
(52HN) FAULT legend comes on.
On R ECAM display - AIR COND page:
A310-200 AMM - CARGO COMPARTMENT
TEMPERATURE CONTROL - ADJUSTMENT/TEST
Revision 32.0
P.Blk EFFECTIVITY: FED ALL
21-64-00-05