- LDG ELEVATION - 10,000 FT
disappears.
10. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:
- reset BULK CARGO/ISOL VALVE - for duration of isolation valve
(FWD CARGO/ISOL VALVE) push- flap movement, ISOL VALVE push-
button switch 6HN (52HN). button switch FAULT legend comes on
and then goes off.
On R ECAM display - AIR COND page:
- isolation valve opens and
color changes to green.
- cold trim air valve flap position
arrow remains at 10 o'clock
(closed) position.
11. On maintenance panel 472VU: On maintenance panel 472VU:
- press MFA RESET push- - BULK/CARGO (FWD/CARGO) MFA
button switch 20WB. goes off.
12. On maintenance panel 471VU: On maintenance panel 471VU:
- rotate ELEC COMPT & CARGO - TEST legend of PTT pushbutton
COMPT selector switch 16WA switch 52WA goes off.
to NORM/FLT position.
13. On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel
A310-200 AMM - CARGO COMPARTMENT
TEMPERATURE CONTROL - ADJUSTMENT/TEST
Revision 32.0
P.Blk EFFECTIVITY: FED ALL
21-64-00-05
Printed - Date: 12/11/12 Time:
Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 52 of 106
JUN 01/2012