FED 401-405,407-414,423-436,443,445-452
1. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:
- press BULK CARGO/ISOL VALVE - OFF/R legend goes off.
(FWD GARGO/ISOL VALVE)push- - for duration of isolation valve
button switch 6HN (52HN). movement, ISOL VALVE pushbutton
switch FAULT legend comes on and
then goes off.
On R ECAM display - AIR COND page:
- isolation valve opens,
- isolation valve color : green.
On maintenance panel 472VU:
- check that BULK/CARGO (FWD/CARGO)
MFA does not come on.
- rotate and hold BULK CARGO On R ECAM display - AIR COND page:
(FWD CARGO) temperature selector - trim air valve flap position arrow
switch 14HN (53HN) in MAN-HOT remains stationary.
position until trim air valve
flap position arrow, on R ECAM
display - AIR COND page, is be-
tween H and C, then release
selector switch.
2. On circuit breaker panel 125VU:
A310-200 AMM - CARGO COMPARTMENT
TEMPERATURE CONTROL - ADJUSTMENT/TEST
Revision 32.0
P.Blk EFFECTIVITY: FED ALL
21-64-00-05
Printed - Date: 12/11/12 Time: