background image

 

DSS2 T-BIS

 – THE MICROPROCESSOR, TRIAC BASED SPEED CONTROLLER – MANUAL 

 

 

 

 

 

 

 

           

             v.2.6  /  II-2017 

DASKO Electronic ul. Do Studzienki 34B, 80-227 Gdańsk /Poland/ tel: (+48) 58 3459107 

[email protected]

  

www.dasko.pl

 

 

1/4 

 1.

 

DESCRIPTION 

Microprocessor, triac-based speed controller for 1-phase motors 
DSS2 T_BIS is available in two versions: 

 

DSS2 T_BIS

 – controlled by 0-10V analog signal (Fig.1) 

 

DSS2  T_BIS_P 

–  controlled  by  0-10V  analog  signal  or  keypad  placed 

on the facade (Fig. 2) 
 

Fig. 1. DSS2 T-BIS_P 

Fig. 2. DSS2 T-BIS_P  

 2.

 

APPLIANCE 

The DSS2 ECO-1.5 speed regulators are designed for voltage speed control 
of single-phase motors. 
 
Typical motors suitable for voltage control: 

 

motors with start up capacitor, 

 

motors with work capacitor, 

 

commutator motors. 

 

WARNING!

  1-phase  asynchronous  motors  cannot  be  controlled  by  DSS2   

T-BIS  speed  regulator.  You  should  always  make  sure  that  the  motor  is 
suitable for voltage control. 

 
Typical DSS2 T-BIS applications: 

 

air handling units and recuperator fans, 

 

heating units fans (water heaters, electric heaters), 

 

small electromechanical equipment, lighting, etc. 

 3.

 

TECHNICAL DATA 

Table 1.  Technical data of DSS2 T-BIS speed controller 

MODEL 

DSS2 T-BIS 

DSS2 T-BIS_P 

Supply voltage 

230V / 50Hz 

Max continuous current 

5 A 

Max peak current 

8 A 

Rated load 

1,0 kW * 

Steering 

0-10 V signal 

keypad / 0-10 V 

IP protection level 

IP 54 

Mounting 

surface / plate mounted 

Signalling 

– 

on keypad 

Steering type 

Phase angle, triac 

PWM frequency 

50 Hz 

Operating temperature range 

-10÷50

o

Storage temperature range 

-30÷60

o

0-10V analog input 

Impedance of 25 kOhm, galvanically 

isolated from the power supply 

Additional voltage source 

Supply source of 16 VDC, 15 mA 

Housing material 

ABS 

Dimensions (HxWxL) 

56x84x124 mm 

Weight 

410 g 

*  given  power  is  an  estimate  -  a  key  parameter  for  the  selection  of  the 
controller is the receiver’s current 

 

 4.

 

CHARACTERISTIC FEATURES 

 

Smooth  adjustment  of  the  output  voltage  over  the  whole  control 
range. 

 

Bimetallic  contact motor protection control. Stop of work and alarm 
indication. 

 

Possibility to change the controller’s settings. 

 

Adjustable output voltage depending on the setpoint of the keypad or 
an external 0-10V signal level. 

 

Possibility  to  combine  multiple  controllers  in  systems  and  control 
them from a single point. 

 

Compact, small and ergonomic design. 

 
 

 5.

 

INSTALLATION 

 

The  DSS2  T-BIS  speed  controller  should  be  mounted  horizontally  on 
the  surface  of  a  wall  or  in  the  control  cabinet  (in  this  case  the 
exchange of air or cooling should be made). 

 

The power must be connected with non-shielded 3x1 mm² cable. 

 

Steering signal must be connected by the shielded cable: 
2x0.5 mm² – for steering by DEN 20, DEN30, PLC etc. 
3x0.5 mm² – for steering by DEN 11. 
The cable shield should be connected to G0 terminal. 

 

The  motor  must  be  connected  with  the  shielded  3x1  mm²  cable.       
The  shield  must  be  connected  to  the  PE  terminal  and  the  motor 
housing. 

 

Cables must be completed with sleeves. 

 

To connect the wires unscrew the four screws that secure the lid and 
then perform the connection according to the diagram in Figure 4. 

 

After  connections  are  made,  close  the  cover  and  switch  the  power 
supply on. 

 

The capacitor should be connected outside of the regulator. 

 

The  regulator  provides  an  additional  input  to  TK  fan  protection.          
It must be connected by 2x1 mm² cable.

 

 

 

WARNING! 

 

It  is  essential  to  disconnect  the  power  before  installing  the 
product. 

 

It is forbidden to run the controller with an open case. 

 

Installation  should  be  performed  by  qualified  personnel  or  the 
service. 

 

Non-authorised changes lead to warranty loss. 

 

It is forbidden to disconnect the load (the motor) while operating. 
By doing so you may damage the controller! 

 

If the T5 fuse blows it is recommended to  try to run a  regulator 
with  an  inserted  F400  fuse  and  disconnected  motor.  If  the  fuse 
does not blow - insert the T5 fuse and start the controller. If the 
fuse blows again, please contact the manufacturer. 