![Federal Signal Corporation SmartSiren Platinum SSP2000B Installation And Maintenance Instructions Manual Download Page 51](http://html1.mh-extra.com/html/federal-signal-corporation/smartsiren-platinum-ssp2000b/smartsiren-platinum-ssp2000b_installation-and-maintenance-instructions-manual_3815024051.webp)
Chapter 7: Testing the Convergence Network
SmartSiren Platinum Convergence Network
51
290A7564
Figure 7.6
LED indicators and fuses on upper part of siren amplifier/relay module
LIGHTBAR ACTIVE:
LED glows in the
SSP3000B when the lightbar is flashing.
AUX PWR:
LED glows in the
SSP3000B when battery power
and serial cable power are present.
SM PWR:
LED glows in the
SSP3000B when the Signal-
Master has power.
SM ON:
LED glows in the SSP3000B
when the SignalMaster flashes a
pattern.
10 A AUX 1–10:
10 A fuses for 10 A auxiliary
solid-state relays. Relays 9/10 can be
configured as 12 Vdc out or ground out.
(Relays 7, 8, 9 are not available on the
SSP2000B)
INPUT 1–4:
LEDs glow in the
SSP3000B when an input is receiving
a signal. Voltage and amperage are
required for the signal.
SM 20A:
20 A fuse for the SignalMaster.
(SSP3000B only)
AUX 11–14:
LED flashes when the output is on for a 2 A
auxiliary solid-state relay. These relays are active-high
only and are internally protected by electronic short-
circuit detection circuits.
AUX 1–10: LED flashes in the SSP3000B
when the output is on for an 10 A auxiliary
solid-state relay. Relays can be configured
as 12 Vdc out or ground out.
RX (Receive):
LED flashes in the SSP3000B
when the relay module receives a message
on the FS Convergence network.
TX (Transmit):
LED flashes in the SSP3000B
when the relay module transmits a message
on the FS Convergence network.
In the SSP3000B each external mini
ATM fuse has an integrated LED that
glows when the fuse is blown.
The table identifies the color
code and amperage.
Color
Amperage
Tan
Red
Yellow