![Federal Signal Corporation SmartSiren Platinum SSP2000B Installation And Maintenance Instructions Manual Download Page 45](http://html1.mh-extra.com/html/federal-signal-corporation/smartsiren-platinum-ssp2000b/smartsiren-platinum-ssp2000b_installation-and-maintenance-instructions-manual_3815024045.webp)
Chapter 6: Setting Control Pad Options
SmartSiren Platinum Convergence Network
45
Selecting Active-High Activation of the Park Input Circuit
For instructions on connecting the control head to the Park Input circuit, see “Park Input (Cable
Assembly P/N 1751542-01 and 1752542-NY)” on page 26.
The default setting is active-low. To select the active-high activation of the Park Input feature:
1.
While in Program Mode, press Button 9. LED 9 in Figure 6.1 turns on.
2.
To continue, select another setting to change or press Button 13 to exit Program Mode. Verify
that the last amber LED turns on when you exit.
Dimming or Turning Off the Button LEDs
To dim or turn off the button LEDs:
1.
While in Program Mode, press
Button 8
up to four times to step though decreasing levels of
brightness (Figure 6.1 on page 44). To turn off the LEDs, press
Button 8
a fifth time.
2.
To continue, select another setting or press
Button 13
to exit Program Mode. Verify that the last
amber LED turns on when you exit.
Configuring Keep-Alive Timeout
For instructions on connecting the ignition sense, see “Connecting Power to the Control Head (with
Ignition Timer)” on page 33. The default setting is to disable the control head immediately with
ignition. To maintain power to the SmartSiren Platinum control head and other Convergence Network
devices after ignition is removed:
1.
While in Program Mode, press
Button 4
. The first press enters the Keep Alive Timeout menu,
and Button 4 starts flashing. Press Button 4 to increase the length of time the control head stays
alive. The amber LEDs indicate the timeout level (Figure 6.2).
2.
To return to the Program Menu, press any other button or wait five seconds. To continue, select
another setting or press
Button 13
to exit Program Mode. Verify that the last amber LED turns
on when you exit.
Figure 6.2
Keep-Alive Timeout durations