![Federal Signal Corporation SmartSiren Platinum SSP2000B Installation And Maintenance Instructions Manual Download Page 24](http://html1.mh-extra.com/html/federal-signal-corporation/smartsiren-platinum-ssp2000b/smartsiren-platinum-ssp2000b_installation-and-maintenance-instructions-manual_3815024024.webp)
Chapter 3: Wiring the Convergence Network
SmartSiren Platinum Convergence Network
24
Figure 3.7
Connection for 2 A solid-state relays
10 8 6 4 2
9
5
7
3 1
AUX
2 3
3
4
4
5 6 7 8
1
11 1 1 1 1
+12v
2
2 3 4
SM
AUX
INPUT
11 12 13 14
WHT/RED
WHT/ORG
WHT/YEL
RELAY LEADS
CABLE ASSY. P/N 1751542-01 (SSP3000B)
AND P/N 1751542-NY (SSP2000B)
AUX
18 AWG
WHT/BLU
Connections for the Latitude SignalMaster
The SSP3000B and SSP2000B both support controlling the Latitude SignalMaster through a
combination of high-current and low-current relays. The relays used for Latitude are shown in
the table below and cannot be changed to other available relays. Enabling these relays to control
the Latitude is done through the Convergence Configuration Software on the SignalMaster
buttons.
For more information on the Latitude see installation manual No. 25500085.
Table 3.3
Latitude SignalMaster control wires
SSP3000B
SSP2000B
Control
Wires
Relay 8
Relay 6
Red
Relay 13
Relay 13
Green
Relay 14
Relay 14
White
Ground
Ground
Black