![Federal Signal Corporation SmartSiren Platinum SSP2000B Installation And Maintenance Instructions Manual Download Page 21](http://html1.mh-extra.com/html/federal-signal-corporation/smartsiren-platinum-ssp2000b/smartsiren-platinum-ssp2000b_installation-and-maintenance-instructions-manual_3815024021.webp)
Chapter 3: Wiring the Convergence Network
SmartSiren Platinum Convergence Network
21
To connect the devices:
1.
Carefully route the cables from the network devices through the vehicle to the connectors on the
siren amplifier/relay module.
2.
To provide strain relief, secure the cables with installer-supplied clamps and hold-downs.
3.
Insert the modular connector at the end of each cable into the appropriate connector.
NOTE:
The 25-foot FS Convergence Network cable must be connected between the control head and
one of the three serial ports (Figure 3.3 on page 19).
Figure 3.4
Serial port locations
SERIAL PORTS:
Connect up to two
Federal Signal serially-
controlled devices.
CONVERGENCE NETWORK
CONNECTIONS:
(to serially
controlled devices)
CONVERGENCE NETWORK
CONNECTION CABLE,
25 FT, P/N 1751357-02:
(to control pad)*
290A7542B
10 8 6 4 2
9
5
7
3 1
AUX
2 3
3
4
4
5 6 7 8
1
11 1 1 1 1
2
2 3 4
AUX
PARK
INPUT
+12V
+
P
RADIO
RING
SPKR
DO NOT EXCEED 5 AMPS
MAXIMUM ON HORN RING
CIRCUIT. SEE INSTALLATION
INSTRUCTIONS
SM
RADIO
RING
SPKR
SERIAL PORTS
Connections for 10 A Auxiliary Relays
Cable assembly P/N 1751541 has 18-inch leads for eight to ten (depending on the model) 10 A
solid state relays with these configurable options:
◆
Eight +12 Vdc out (active high)
◆
Two +12 Vdc out (active high) or negative (–) ground out (active low)
◆
Steady-on or one of five flash rates for small flashing lights.
◆
Synchronized or alternating flashing for two or more lights.
◆
Open-off or inverse-off operation.
NOTE:
The Model SSP2000B has one high-low 10 A relay. The rest are +12 Vdc only relays.