UVIC OPERATION
42
3.7 Sensor Inputs and Isolated
Sensor Power
Terminal block
JP15 at the bottom of the
system motherboard is the Sensor
Inputs. These are activated by a short to
“Common”.
Sensor Connections:
JP15
Terminal
Function
1 “Common”
2 “Spare
#1”
3 “Common”
4 “Intrusion”
5 “Common”
6 “Solar”
7 “Common”
8 “AC
Power”
9 “Common”
10 “600
PTT”
11 “Common”
12 “Spare
#2”
Isolated Supply used to power
External Sensors
JP16
Terminal
Function
1
“Isolated Supply (Ground)”
2
“Isolated Supply (+5V)”
Intrusion: Alerts the controller when one
of the unit’s doors has been
opened. Low is intrusion pass
Solar:
Used to sense operation of
solar power system.
Jumper JP15: pins 5 to 6 and
to enable solar sensing. Solar
mode latches power sense to
prevent low light conditions
from causing failures. For
solar panel test, initiate a
reset, and then a poll.
Immediate good power input
required after a reset to pass.
Jumper JP15 pins 7 to 8 AC
sense is required if solar only
unit.
Spare
1 & 2:
Unused inputs for special
functions.
AC
Power: Alerts the controller when the
AC Power has failed. Open is
fail. Closed is
pass.
600 Ohm
PTT:
Puts the unit in Local PA
mode for input of external
audio. Closed is active.
Summary of Contents for Personnel Alerting System
Page 49: ...INSTALLATION 49 Figure 5 2 UVIC Cabinet Dimensional Outline Drawing ...
Page 50: ...INSTALLATION 50 Figure 5 3 UVIC Wiring Diagram ...
Page 51: ...INSTALLATION 51 Figure 5 4 UVIC Battery Connections ...
Page 62: ...INSTALLATION 62 Figure 5 5 Yagi Antenna Installation Example ...
Page 63: ...INSTALLATION 63 Figure 5 6 Omni Antenna Installation Example ...
Page 64: ...INSTALLATION 64 Figure 5 7 Antenna Grounding Example ...
Page 69: ...INSTALLATION 69 Figure 5 10 UVLOC Dimensional Outline ...
Page 70: ...INSTALLATION 70 Figure 5 11 UVIC25SD Field Wiring Diagram ...
Page 83: ...83 Figure 9 1 UVIC Final Assembly and Parts List Page 2 of 2 ...
Page 84: ...UVIC Final Assembly and Parts List 84 Figure 9 2 UVIC25ST Wiring Detail ...