86
Installing and Configuring the I/O Cards
PAGASYS GEN II (P-SYS-G)
Federal Signal www.fedsig.com
To install and configure the Fan Wiring Termination card (P-FWTC-G):
1. Ensure that the AC or DC power supplies serving the P-FWTC-G card and all other
connected equipment are turned off and isolated.
2. Place the P-FWTC-G card on to its housing mounting pillars and fasten to the pillars
using the screws supplied or previously removed.
3. While referencing the cabinet wiring drawings and the Technical Installation Guide,
connect the P-FWTC-G connectors to the system fan wiring.
6.11 IS Barrier Board (P-IS-BARRIER-G)
6.11.1 Removing the IS Barrier Board (P-IS-BARRIER-G)
To remove the IS Barrier Board (P-IS-BARRIER-G):
1. Before removing or installing the P-IS-BARRIER-G card, ensure that all AC and DC
power supplies serving the cabinet are turned off and isolated. This should remove
any live voltages generated with the cabinet from the terminal blocks of the P-IS-
BARRIER-G.
2. Referencing the rack wiring drawings disconnect the P-IS-BARRIER-G connectors
to the Access Panel wiring.
3. While supporting the P-IS-BARRIER-G card, remove the screws that hold the P-IS-
BARRIER-G on its mounting pillars. Store the screws in a safe place for reuse.
4. Remove the P-IS-BARRIER-G card from its mounting pillars.
6.11.2 Installing and Configuring the IS Barrier Board
Avoid locating the equipment near heat sources, in direct sunlight, and where it is
exposed to high humidity or dust levels.
Before removing or installing the P-IS-BARRIER-G card, ensure that all AC and DC
power supplies serving the cabinet are turned off and isolated.
AUTOMATIC EQUIPMENT WARNING: This equipment is part of an automated
system. When installing or servicing this equipment or any other part of the
warning system, you must be aware that the system could energize circuits
and signals at any time. Use extreme caution to protect yourself from electric
shock, loud sounds, and bright light that could be generated by the system.
To avoid these hazards, always disconnect power to all of the system and
its components, including battery backup power supplies when installing or
servicing any part of the warning system.