26
General Description
PAGASYS GEN II (P-SYS-G)
Federal Signal www.fedsig.com
Figure 7 Amplifier Audio Mux Card (P-AAMC-G)
Table 8 Environmental and Physical for the Amplifier Audio Multiplexer Card
(P-AAMC-G)
Operating Temperature
-10 to +55°C
Humidity
0-98% non-condensing
P-AAMC-G Dimensions (H x W x L)
45 mm x 343.9 mm x 152.25 mm
Weight
0.41 kg/0.90 lb
2.5.8 Internal AP Mux Card (P-IAMC-G)
The Internal Access Panel Multiplexer card (P-IAMC-G) provides the interface to
connect eight Access Panels or Microphone Stations to a System Controller. (See Figure
8.) Install the P-IAMC-G card in the System Controller Chassis in AP MUX slots 1 or 2,
or in both slots. See the External Access Panel Multiplexer card (P-EAMC-G) for another
option for these two System Controller AP MUX slots.
Access Panels connected to the P-IAMC-G are numbered differently depending on
the installation of the P-IAMC-G. If installed into AP MUX slot 1, Access Panels are
numbered from 1 to 8. If installed into AP MUX slot 2, the Access Panels are numbered
from 17 to 24.