![Federal Signal Corporation PAGASYS GEN II P-SYS-G Description, Installation, Operations And Maintenance Manual Download Page 30](http://html.mh-extra.com/html/federal-signal-corporation/pagasys-gen-ii-p-sys-g/pagasys-gen-ii-p-sys-g_description-installation-operations-and-maintenance-manual_548461030.webp)
30
General Description
PAGASYS GEN II (P-SYS-G)
Federal Signal www.fedsig.com
Figure 10 Miscellaneous I/O Card (P-CMC-G)
Table 11 Environmental and Physical for the Miscellaneous I/O Card (P-CMC-G)
Operating Temperature
-10 to +55°C
Humidity
0-98% non-condensing
P-CMC-G Dimensions (H x W x L)
45 mm x 343.9 mm x 171.9 mm
Weight
0.38 kg/0.84 lb
2.5.11 I/O Interface Card (P-IOIC-G)
The I/O Interface card (P-IOIC-G), provides I/O interfaces for the System Controller.
(See Figure 11.)
The P-IOIC-G card provides four electrically isolated half-duplex RS485 serial port
interfaces for communication with the I/O modules used in the system, and a 24 Vdc
supply to power these I/O modules.
The P-IOIC-G card also provides one electrically isolated I
2
C bus for communication
with legacy PAGASYS I/O modules, and a 24 Vdc supply to power the I/O modules.
NOTE
: The service model for the I/O Interface card is K-P-IOIC-G.