4.4.7. Display setting
Description
Measurement value to be displayed in display unit and display kind can be selected from the following.
(1) Selection
Measurement value to be displayed can be selected from the following.
Velocity: Instantaneous
velocity
[m/s]
Total forward *
1
: Total value in forward direction
Total reverse *
1
: Total value in reverse direction
F: Total pulse:
Total pulse in forward direction
R: Total pulse:
Total pulse in reverse direction
Flow rate (%):
Percentage of analog output to the range
Flow rate:
Instantaneous flow rate
If flow rate is selected, select the unit of flow rate from the following.
L/s, L/min, L/h, L/d, kL/d, ML/d
m
3
/s, m
3
/min, m
3
/h, m
3
/d, km
3
/d, Mm
3
/d
BBL/s, BBL/min, BBL/h, BBL/d, kBBL/d, MBBL/d
*1) The unit of Total forward/Reverse forward is the unit of Total.
(2) Setting of decimal point position of numeric value display
Measurement data is displayed in the range of 10 (including decimal point).
The number of decimal places can be set arbitrarily within the display range.
Operation
(example)
When displaying instantaneous flow rate of display 1 in unit of m
3
/h, and display 2 in unit of flow
rate (%)
Key operation
Description
Display
FUNC DISP
Display “1: DISPLAY KIND”
1: DISPLAY KIND
FLOW RATE
#
Select “1: DISPLAY UNIT”
1: DISPLAY UNIT
m
3
/h
ENTER
"
or
#
ENTER
Enter select/enter mode, select “m
3
/h,” and
press ENTER.
2: DISPLAY KIND
m
3
/h
#
Select “2: DISPLAY KIND”
2: DISPLAY KIND
VELOCITY
ENTER
"
or
#
ENTER
Enter select/enter mode, select “FLOW
RATE (%),” and press ENTER.
2: DISPLAY KIND
FLOW RATE (%)
ESC
Display the measurement, reflecting the
setting.
(Measurement display screen)
Operation
(example)
When displaying display 1 up to the third decimal places, and not displaying the digits to the right of
the decimal point of display 2
Key operation
Description
Display
Display
“DISPLAY
SETTING”
100.00%
112.63 m
3
/h
%
or
&
Display “
'
,
(
” on both sides of the value
of display 1.
100.00%
'
112.63
(
m
3
/h
%
The value of display 1 shifts to left.
100.00%
'
112.639 m
3
/h
"
Display “
'
,
(
” on both sides of the value
of display 2.
'
100.00
(
%
112.639 m
3
/h
&
The value of display 2 shifts to right.
'
100
(
%
112.639 m
3
/h
ENTER
Reflect the setting.
100%
112.639 m
3
/h