- 30 -
INF-TN1FSH-E
3.5.4. Mounting the sensor unit by Z method using a frame
(2 measurement lines)
(1) Mounting
the
frame
Two pairs of frames are required.
(1) Draw a mark-off line at an angle
±
45
°
from the horizon. See 3.5.5. (1) how to draw a mark-off line.
(2) Align the center of the end frame so that it comes over the make-off line, and temporarily fasten it using cloth
belt, etc. not on the frame ends but on the frame.
(3) Then wrap a stainless steel belt around the frame end to fasten it securely. Follow the description in 3.5.3. to
fasten the stainless steel belt.
(2) Mounting the sensor unit
Two pairs of sensor units and two pairs of absorbers (in the case of a metal pipe) are required for mounting. Mount the
sensor units following the same procedure as “3.5.3. (3) How to mount the sensor unit.” Mount each pair of frames to
install the sensor unit.
45
°
45
°
Mark-off line
Mark-off line
45
°
45
°
Frame