INF-TN1FSH-E
- 85 -
Operation
(example)
When setting window control of line 2 to manual, open time (F/R) to 150
µ
s, and measurement method
to method 1
Key operation
Description
Display
FUNC DETAIL
Display VERSION INF.
VERSION INF.
SKIP
"
or
#
Select “TRANSIT TIME”
TRANSIT TIME
SKIP
ENTER
"
or
#
ENTER
Enter select/enter mode, select “SETTING,”
and press ENTER.
LINE SELECT NO.
LINE 1
ENTER
"
or
#
ENTER
Enter select/enter mode, select “LINE 2,”
and press ENTER.
2: TRANS. COUNT
128
"
or
#
Select “2: WINDOW CONTROL”
2: WINDOW CONTROL
AUTO
ENTER
"
or
#
ENTER
Enter select/enter mode, select
“MANUAL,” and press ENTER.
2: WINDOW CONTROL
MANUAL
#
Select “2: OPEN TIME (F)”
2: OPEN TIME (F)
0 us
ENTER 1 5 0 ENTER
Enter numeric value enter mode, enter
“150” using ten keys, and press ENTER.
2: OPEN TIME (F)
150 us
#
Select “2: OPEN TIME (R)”
2: OPEN TIME (R)
0 us
ENTER 1 5 0 ENTER
Enter numeric value enter mode, enter
“150” using ten keys, and press ENTER.
2: OPEN TIME (R)
150 us
"
or
#
Select “2: MEAS. METHOD”
2: MEAS. METHOD
METHOD 2
ENTER
"
or
#
ENTER
Enter select/enter mode, select “METHOD
1,” and press ENTER.
2: MEAS. METHOD
METHOD 1
ESC ESC ESC
Display the measurement, reflecting the
setting.
(Measurement display screen)