![FCI ST100 series Installation, Operation & Maintanance Manual Download Page 87](http://html.mh-extra.com/html/fci/st100-series/st100-series_installation-operation-and-maintanance-manual_547358087.webp)
ST100 Series Flow Meter
APPENDIX C - ADDITIONAL INFORMATION
Fluid Components International LLC
81
■ Send to Device (button)
▬ Modbus
■ Modbus (frame)
– Node ID: (text box)
– Mode: (drop-down list)
– Baud: (drop-down list)
– Data Bits: (drop-down list)
– Parity: (drop-down list)
– Stop Bits: (drop-down list)
□ Get from Device (button)
□ Send to Device (button)
▬ Extended Operational Mode
■ System Mode (frame)
– Toggle System Mode: (button)
■ Extended Operational Mode (frame)
– Basic (radio button)
– External Input Flow Adjust (EIA) (radio button)
– External ST100 Flow Input (EFI) (radio button)
– Auto FE Calibration Group Switching (FCS) (radio button)
– External Control Group Switching (EGS) (radio button)
■ Ext. Input Flow Adjust Setup (frame)
– Factor1: (text box)
– Factor2: (text box)
– Factor3: (text box)
– Factor4: (text box)
■ Ext. ST100 Flow Input Setup (frame)
– (Ext. ST100) Flow Units: (drop-down list)
– (Ext. ST100) Flow Min (4mA): (text box)
– (Ext. ST100) Flow Max (20mA): (text box)
■ Get from Device (button)
■ Send to Device (button)
■ Set System Mode to “Running:” when Send (check box)
▬ Group Switch Setup
■ AUTO FE Calibration Group Switching Setup (frame)
■ External Control Group Switching Setup (frame)
● D
iagnostics
▬ Status
■ Faults, FE Status (scrollable text box)
■ Get from Device (button)
▬ Fault Log
■ Fault log list (scrollable text box)
■ Get from Device (button)
■ Clear Fault Log (button)
■ Add to SD Card Log (button)
▬ Scheduled Tasks
■ FE # (drop-down list)
■ Internal Delta-R Resistor Check (frame)
– Mode (drop-down list)
– Day, #days, DOW (spinner)
– Time (spinner)
– Run Check Now (button)
■ Get from Device (button)
■ Send to Device (button)
▬ Test Logs
■ Test log list (scrollable text box)
■ Get from Device (button)
■ Clear Test Logs (button)
■ Add to SD Card Logs (button)
● f
actory
▬ Factory Parameters
■ Calibrated Min / Max (frame)
– Min & Max Flow (text boxes, Std feet per second)
– Min & Max Temp (text boxes, Degrees F)
– Min & Max Press (text boxes, psi (g))
■ Get from Device (button)
■ Send to Device (button)
— Identification
■ General (frame)
– Internal CORE S/W version (text box)
– Customer name (text box)
– Device CO (text box)
– Device S/N (text box)
– HMI S/W version (text box)
■ Unit MAC Address (frame)
– MAC address (6 octets, spinner for each)
■ Get from Device (button)
■ Send to Device (button)
— 4-20mA Factory
■ 4-20mA #1 Settings (frame)
– Min DAC (4 mA) (spinner)
– Max DAC (20 mA) (spinner)
– Manual DAC Counts (spinner)
– Click to Output Manual (button)
■ 4-20mA #2 Settings (frame)
– Min DAC (4 mA) (spinner)
– Max DAC (20 mA) (spinner)
– Manual DAC Counts (spinner)
– Click to Output Manual (button)
■ 4-20mA #3 Settings (frame)
– Min DAC (4 mA) (spinner)
– Max DAC (20 mA) (spinner)
– Manual DAC Counts (spinner)
– Click to Output Manual (button)
■ 4-20mA Input (frame)
– Raw A/D Counts (text box)
– Gain (text box)