APPENDIX A - OUTLINE DIMENSIONAL DRAWINGS
Fluid Components International LLC
51
.80
20
.88
22
.88
22
VERTICAL
FLOW ORIENTATION
SHOWN
HORIZONTAL
FLOW ORIENTATION
SHOWN
Y
5.00 127
5.00 127
X
.25 6
Z
3.27 83
3.90
MAX
99
7.75 197
2.80 71
2.22 57
2X
.75 19
2X
2.25 57
2X
1.75 44
2X
1.44 37
2X
4.25 108
2X
2.88 73
4X
.31 8
4X
.40 10
8.00
MAX
7.
203
"U" LENGTH
3.54
90
SPECIFICATIONS
Customer: Purchase Order No: Customer Order No: Wetted Surface Material: Max Element Operating Temp: Ferrule Type: U Length: Serial No: Tag No:
"FPC" STYLE HEAD
"FP" STYLE HEAD
"S" STYLE HEAD
MOUNTING BRACKET
2X M4 SCREWS
4X 1/2 INCH NPT
OR M20X1.5
OPTIONAL DISPLAY
2X 1/2 INCH NPT
OR M20X1.5
MOUNTING ORIENTATION OF FLATS
TO BE PARALLEL TO FLOW
6.
COMPRESSION FITTING
OPTIONAL TEFLON OR METAL FERRULE
M4 GROUND SCREW
LOCAL ENCLOSURE MEETS EXPLOSION PROOF, WATER AND DUST TIGHT APPROVALS. (SEE MANUAL FOR SPECIFIC APPROVIAL TYPES)
REMOTE ENCLOSURE MEETS EXPLOSION PROOF, WATER AND DUST TIGHT APPROVALS. (SEE MANUAL FOR SPECIFIC APPROVIAL TYPES)
PROCESS CONNECTION
OPTIONAL 3/4 INCH NPT OR 1 INCH NPT
GROUND SCREW
ALUMINUM
SST
X
11.00
13.00
Y
7.00
9.25
Z
4.50
6.75
NEXT ASSY
THIRD ANGLE PROJECTION
A
8
B
7
6
5
C
D
8
7
6
5
OUTLINE/INSTALLATION DRAWING
CONTRACT NO.
4
DECIMALS
MACH SURFACE
UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES
DO NOT SCALE DRAWING
.XXX ±.010
.XX ±.03
.X ±.1
FINISH: 125 RMS
USED ON
APPLICATION
MATERIAL
±1/2°
MACH RAD:
.030
MFG
QA
QUAL
CONTRACT
ANGULAR
TOLERANCES
3
2
APPROVALS
ENGR
CHECK
DRAWN
TITLE
APPROVALS
D
SIZE
CAGE CODE
1
DWG NO.
SCALE
SHEET
REV
B
4
3
2
C
1
D
HAZARDOUS LOCATION, REMOTE
TRANSMITTER, ST100 & ST102A
COMPRESSION FITTING
04/17/12
04/17/12
04/05/12
Anthony Doerrer
FOUAD CHIRAR
BURT TANAKA
FOUAD CHIRAR
NANCY PETERS
04/17/12
04/17/12
N/A
004872
1 OF 1
B
PARTS TO BE FREE OF BURRS & SHARP EDGES
DATE
DESCRIPTION
REV
REVISIONS
NOTED
NOTES: UNLESS OTHERWISE SPECIFIED
64818
FLUID COMPONENTS INTERNATIONAL LLC
R
SAN MARCOS, CA 92078
MAJOR CHANGE - SEE DCN (REVISED AND REDRAWN)
11/15/12
B
A
only (and does not include manufacture or processing uses). Any
other use is strictly prohibited
you is expressly conditioned upon your assent that its use is l
imited to use within your company
information which is the property of Fluid Components Internati
onal (FCI). Disclosure of this data to
This document contains confidential technical data, including t
rade secrets and proprietary
without prior written consent of FCI.
NOTICE OF PROPRIETARY RIGHTS
REMOTE ELECTRONICS ASSEMBLY
FLOW ELEMENT ASSEMBLY 8.
8.
QUANTITY OF TWO (2) FLOW ELEMENT ASSEMBLIES PROVIDED FOR ST102A
MODELS.
7.
MAXIMUM DIMENSION WHEN FLOW ELEMENT IS INSTALLED TO CUSTOMER RE
QUIRED
"U" LENGTH
6.
COMPRESSION FITTING SPECIFICATIONS: - TEFLON FERRULE: 150 PSIG [10 BAR(G)] MAX; 200
F [93
C] MAX.
- METAL FERRULE: 1000 PSIG [69 BAR(G)] MAX; 500
F [260
C] MAX.
5. SEE IO&M MANUAL FOR ADDITIONAL INFORMATION AND INSTRUC
TION.
4. ALL ORIENTATIONS AND/OR MOUTING REFERENCES ARE INDICAT
ED FROM TERMINAL
ENCLOSURE END OF SENSING ELEMENT.
3. FOR ELECTRICAL OPTIONS, CONNECTIONS AND TESTS, SEE APP
LICABLE WIRING
DIAGRAM.
2. THIS DRAWING IS REFERENCE DOCUMENT ONLY.
1. DIMENSIONS IN BRACKET [ ] ARE IN MILLIMETERS.