![FCI ST100 series Installation, Operation & Maintanance Manual Download Page 67](http://html.mh-extra.com/html/fci/st100-series/st100-series_installation-operation-and-maintanance-manual_547358067.webp)
ST100 Series Flow Meter
APPENDIX B - WIRING DIAGRAMS
Fluid Components International LLC
61
Figure B-3 – Integral: DC Input Power, Analog and HART Output
Figure B-4 – Remote: DC Input Power, Analog and HART Output
DC Input Power
24 VDC 20%
Customer Connection
16-22 Ga Wire
ANALOG OUTPUT (HART)
ANALOG OUTPUT
1
2
4
6
3
5
(-)
(+)
(+)
(-)
(+)
(-)
CUSTOMER CONNECTIONS
HART OUTPUT IS ALWAYS ON CH1
CH 1 (INT)
CH 1 (EXT)
CH2
CH3
(-)
(+)
C00999-1-3
ANALOG OUTPUT (HART)
ANALOG OUTPUT
1
2
4
6
3
5
(-)
(+)
(+)
(-)
(+)
(-)
CUSTOMER CONNECTIONS
HART OUTPUT IS ALWAYS ON CH1
CH 1 (INT)
CH 1 (EXT)
CH2
CH3
(-)
(+)
DC Input Power
24 VDC 20%
Customer Connection
16-22 Ga Wire
Remote Cable, Shielded
300-1000 ft
Remote Flow Transmitter
(Element)
C01116-1-1