![FCI ST100 series Installation, Operation & Maintanance Manual Download Page 58](http://html.mh-extra.com/html/fci/st100-series/st100-series_installation-operation-and-maintanance-manual_547358058.webp)
APPENDIX A - OUTLINE DIMENSIONAL DRAWINGS
ST100 Series Flow Meter
52
Fluid Components International LLC
VERTICAL
FLOW ORIENTATION
SHOWN
HORIZONTAL
FLOW ORIENTATION
SHOWN
Y
5.00 127
5.00 127
X
.25 6
Z
7.75 197
2.80 71
2.22 57
2X
.75 19
2X
2.25 57
2X
1.75 44
2X
1.44 37
2X
4.25 108
2X
2.88 73
4X
.31 8
4X
.40 10
4.68 119
5.40 137
6.50
MAX
165
"U" LENGTH
4.83 123
4.28 109
1.13
TYP
29
15.50
394
MAX
7.
"FP" STYLE HEAD
"FPC" STYLE HEAD
MOUNTING BRACKET
2X M4 SCREWS
4X 1/2 INCH NPT
OR M20X1.5
OPTIONAL DISPLAY
MOUNTING ORIENTATION OF
FLATS TO BE PARALLEL TO FLOW
6.
LOW PRESSURE PACKING GLAND.
(TEFLON OR GRAPHITE PACKING MATERIAL)
LOCAL ENCLOSURE MEETS EXPLOSION PROOF WATER AND DUST TIGHT APPROVALS. SEE MANUAL FOR SPECIFIC APPROVIAL TYPES
"S" STYLE HEAD
LOCKING COLLAR
REMOTE ENCLOSURE MEETS EXPLOSION PROOF, WATER AND DUST TIGHT APPROVALS. (SEE MANUAL FOR SPECIFIC APPROVIAL TYPES)
M4 GROUND SCREW
1 1/4 INCH NPT PROCESS CONNECTION
1 INCH NPT PORT
M4 GROUND SCREW
ALUMINUM
SST
X
11.00
13.00
Y
7.00
9.25
Z
4.50
6.75
NEXT ASSY
THIRD ANGLE PROJECTION
A
8
B
7
6
5
C
D
8
7
6
5
OUTLINE/INSTALLATION DRAWING
CONTRACT NO.
4
DECIMALS
MACH SURFACE
UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES
DO NOT SCALE DRAWING
.XXX ±.010
.XX ±.03
.X ±.1
FINISH: 125 RMS
USED ON
APPLICATION
MATERIAL
±1/2°
MACH RAD:
.030
MFG
QA
QUAL
CONTRACT
ANGULAR
TOLERANCES
3
2
APPROVALS
ENGR
CHECK
DRAWN
TITLE
APPROVALS
D
SIZE
CAGE CODE
1
DWG NO.
SCALE
SHEET
REV
B
4
3
2
C
1
D
HAZARDOUS LOCATION, REMOTE
TRANSMITTER, ST100 & ST102A
1 1/4 INCH NPT PGL
04/17/12
04/17/12
04/05/12
Anthony Doerrer
FOUAD CHIRAR
BURT TANAKA
FOUAD CHIRAR
NANCY PETERS
04/17/12
04/17/12
N/A
004852
1 OF 1
B
PARTS TO BE FREE OF BURRS & SHARP EDGES
DATE
DESCRIPTION
REV
REVISIONS
NOTED
NOTES: UNLESS OTHERWISE SPECIFIED
64818
FLUID COMPONENTS INTERNATIONAL LLC
R
SAN MARCOS, CA 92078
MAJOR CHANGE - SEE DCN (REVISED AND REDRAWN)
11/19/12
B
A
only (and does not include manufacture or processing uses). Any
other use is strictly prohibited
you is expressly conditioned upon your assent that its use is l
imited to use within your company
information which is the property of Fluid Components Internati
onal (FCI). Disclosure of this data to
This document contains confidential technical data, including t
rade secrets and proprietary
without prior written consent of FCI.
NOTICE OF PROPRIETARY RIGHTS
REMOTE ELECTRONICS ASSEMBLY
FLOW ELEMENT AND PACKING
GLAND ASSEMBLY
8.
QUANTITY OF TWO (2) FLOW ELEMENT ASSEMBLIES PROVIDED FOR ST102A
MODELS.
7.
MAXIMUM DIMENSION WHEN FLOW ELEMENT IS INSTALLED TO CUSTOMER REQUIRED "U" LENGTH
6.
PACKING GLAND SPECIFICATIONS:
- MAXIMUM OPERATING TEMPERATURE, TEFLON PACKING: 500
F [260
C]
- MAXIMUM OPERATING TEMPERATURE, GRAPHITE PACKING: 85
0
F [454
C]
- MAXIMUM OPERATING PRESSURE, 50 PSIG [3.5 BAR (G)]
5. SEE IO&M FOR ADDITIONAL INFORMATION AND INSTRUCTION.
4. ALL ORIENTATIONS AND/OR MOUTING REFERENCES ARE INDICAT
ED FROM TERMINAL
ENCLOSURE END OF SENSING ELEMENT.
3. FOR ELECTRICAL OPTIONS, CONNECTIONS AND TESTS, SEE APP
LICABLE WIRING
DIAGRAM.
2. THIS DRAWING IS REFERENCE DOCUMENT ONLY.
1. DIMENSIONS IN BRACKET [ ] ARE IN MILLIMETERS.
SPECIFICATIONS
Customer: Purchase Order No: Customer Order No: Wetted Surface Material: Max Element Operating Temp: Packing Material: U Length: Serial No: Tag No:
8.