![FCI ST100 series Installation, Operation & Maintanance Manual Download Page 60](http://html.mh-extra.com/html/fci/st100-series/st100-series_installation-operation-and-maintanance-manual_547358060.webp)
APPENDIX A - OUTLINE DIMENSIONAL DRAWINGS
ST100 Series Flow Meter
54
Fluid Components International LLC
7.74 197
3.62 92
4.12 105
X
X/2
7.
"A" LENGTH
10.00
MAX
254
5.42 138
7 DIA
2 DIA
5.00 127
SPECIFICATIONS
Customer: Purchase Order No: Customer Order No: Wetted Surface Material: Max Element Operating Temp: Line Type Connection: Line Size: A Length: Serial No: Tag No:
MOUNTING ORIENTATION OF FLATS TO BE PARALLEL TO FLOW
6.
COMPRESSION FITTING
REMOTE ENCLOSURE MEETS EXPLOSION PROOF,
WATER AND DUST TIGHT APPROVALS.
(SEE MANUAL FOR SPECIFIC APPROVAL TYPES)
OPTIONAL DISPLAY
OPTIONAL VORTAB
M4
GROUNDING SCREW
4X 1/2 INCH NPT OR
M20X1.5
2X FLANGE
LINE CONNECTION
SENSOR ELEMENT TYPES:
"F" OR "S" STYLE,
FLOW DIRECTION
8.
2 INCH SCH 40 PIPE SHOWN
8.
9.
BUTT WELD
FEMALE NPT
MALE NPT
OPTIONAL
LINE
CONNECTION
TYPES
LINE SIZE
"A" LENGTH
1"
9"
1 1/2"
13.5"
2"
18"
NEXT ASSY
THIRD ANGLE PROJECTION
A
8
B
7
6
5
C
D
8
7
6
5
OUTLINE/INSTALLATION DRAWING
4
DECIMALS
MACH SURFACE
UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES
DO NOT SCALE DRAWING
.XXX ±.010
.XX ±.03
.X ±.1
FINISH: 125 RMS
USED ON
APPLICATION
MATERIAL
±1/2°
MACH RAD:
.030
ANGULAR
TOLERANCES
3
2
TITLE
D
SIZE
CAGE CODE
1
DWG NO.
SCALE
SHEET
REV
B
4
3
2
C
1
D
EXPLOSION PROOF, LOCAL
TRANSMITTER, ST100L INLINE PIPE SPOOL
N/A
004873
1 OF 1
A
PARTS TO BE FREE OF BURRS & SHARP EDGES
DATE
DESCRIPTION
REV
REVISIONS
NOTED
NOTES: UNLESS OTHERWISE SPECIFIED
64818
FLUID COMPONENTS INTERNATIONAL LLC
R
SAN MARCOS, CA 92078
A
only (and does not include manufacture or processing uses). Any
other use is strictly prohibited
you is expressly conditioned upon your assent that its use is l
imited to use within your company
information which is the property of Fluid Components Internati
onal (FCI). Disclosure of this data to
This document contains confidential technical data, including t
rade secrets and proprietary
without prior written consent of FCI.
NOTICE OF PROPRIETARY RIGHTS
A
04/12/12
INITIAL RELEASE
9.
SEE TABLE FOR AVAILABLE CONNECTION TYPES.
8.
SEE TABLE FOR AVAILABLE PIPE SIZES.
7.
FLANGE MOUNTING HOLES TO STRADDLE PIPE CENTERLINE.
6.
COMPRESSION FITTING SPECIFICATIONS:
- METAL FERRULE 1000 PSIG [69 BAR] MAX, 500
F [260
C ] MAX
(LIMITATION OF PRESSURE IS DEPENDENT ON FLANGE RATING
)
5. SEE IO&M MANUAL FOR ADDITIONAL INFORMATION AND INSTRUC
TION.
4. ALL ORIENTATIONS AND/OR MOUTING REFERENCES ARE INDICAT
ED FROM TERMINAL ENCLOSURE END OF
SENSING ELEMENT.
3. FOR ELECTRICAL OPTIONS, CONNECTIONS AND TESTS, SEE APP
LICABLE WIRING DIAGRAM.
2. THIS DRAWING IS REFERENCE DOCUMENT ONLY.
1. DIMENSIONS IN BRACKET [ ] ARE IN MILLIMETERS.