FCI WATERMAKERS, INC.
52
Operational Instructions
SYSTEM FUNCTIONALITY
Standby Mode
When the machine is at rest, the unit will be in Standby Mode.
This is the only time the system can be started.
When the system is in Standby Mode:
• LPV is off.
• HPP is off.
Running Mode
At any point during Standby Mode the system can be started by pressing the Start Button
on the Home Screen. Once the system starts you will then be taken to the Prime Screen.
Prime
During the Prime Sequence :
• LPV turns on. The valve status is then verified by the Low Pressure
Switch. It must be greater than 3 PSI or the system will shutdown.
• HPP remains off.
The Prime Timer counts down from its setpoint, Prime Timer Setpoint (which is user
adjustable by navigating to Setup Screen and the Timing Screen). Once the timer
reaches zero, the timer has expired and the system then moves to Initialize Sequence.
Timer
– Indicates time left in seconds for the Prime Sequence.
Clear
– Press this button to clear the system once a shutdown has taken place.
Stop
– Press this button to stop the system.
Navigation Bar
– This allows the user to easily navigate between main screens.
Right Arrow
– When pressed, will proceed to the Initialize Sequence.
SYSTEM FUNCTIONALITY
The system modes and their sequencing are
described in the following pages.