FCI WATERMAKERS, INC.
43
Operational Instructions
OPERATING THE DTS
+SOLO
Refer to
and follow the procedures
below to operate the DTS
+SOLO
.
START-UP PROCEDURE
Proceed as follows:
1. Check to be sure all Inlet/Discharge valves are open, fully open Reject Flow knob,
fully close Recycle Flow knob, and check the main breaker is turned on. Display
will show FCI Watermakers, press the water logo to proceed to home screen.
2. Press the Start button: The Low-Pressure Solenoid will engage
and the display screen will indicate “Prime” mode in the top
right corner. System will prime for time span indicated.
3. After “Prime” mode times out, the High-Pressure Pump will engage and the
display screen will be in “Initialize” mode as indicated in the top right corner of
the display. System will initialize for the time span indicated. At this time, slowly
close the Reject Flow knob until you are making your rated output. Once stable,
slowly open the Recycle Flow and set to approximately 50% of rated output.
Adjustment to the Reject Flow knob may be necessary to maintain rated output.
4. After “Initialize” mode times out the unit will be in “Run” mode.
SHUTDOWN PROCEDURE
Press the Stop button: System will shutdown and return to the home screen.
DTS
+SOLO
Control System HMI Touchscreen
(Start and stop system by touching icons)
Read Product PPM
and Temperature
from HMI Touchscreen
Startup Instructions Decal
Recycle Flow Adjustment Valve
(Set recycle flow to 50% of rated output)
Reject Flow Adjustment Valve
(Set product flow to rated output)
Figure 19: Operating the DTS
+SOLO