the keypad buzzer and transmit to the central station, if programmed.
THE KEYPAD BUZZER CAN BE SILENCED by entry of any valid user
code. When AC restores the AC/LOW BAT LED will light immediately,
and a restore code will be reported, if programmed.
BACKUP BATTERY:
The RED (+) and BLACK (-) flying leads must be connected to a 12 VDC
4-6AH GELL CELL, to serve as backup power in the event of AC loss.
A battery test occurs approximately every 4.5 minutes. Low battery
condition occurs at nominal 11VDC. The keypad AC/LOW BAT LED and
buzzer will PULSE SLOWLY when a low battery condition is detected.
The system reports this condition to the CS if programmed. Battery
restoral will occur WITHIN 4.5 minutes, at the NEXT battery test. THE
BUZZER MAY BE SILENCED by entry of any valid user code.
GROUND START:
Ground start capability can be added to the system through addition of
the FBII Model 117 module. Consult the 117 Installation Instructions for
hookup information. With this device some systems can obtain dialtone
where it is not available. At the moment telephone line seizure occurs,
the Telco Tip is momentary connected to earth ground to access dial tone.
NOTE: The 117 module has not been tested for use in UL installations.
P1: VBELL, T1 & T2 TRIGGER OUTPUTS (1 & 2):
The control panel contains two programmable trigger outputs. Trigger #1
terminals are P1-VBELL (+) & P1-T1 (-) and for Trigger #2 P1-VBELL (+)
& P1-T2 (-). See programming question #07, location 4 for valid trigger
types. BY DEFAULT TRIGGER #1 IS ENABLED FOR SMOKE
DETECTOR POWER, WHICH CAN ALSO BE OBTAINED FROM
TERMINALS 12(+) & 13(-). TRIGGER #2 CANNOT BE SELECTED FOR
SMOKE POWER. NOTE: In order to connect devices to the triggers use
connector XL-2GTC (trigger cable). Unless otherwise specified, the
trigger output is normally floating and actively sinks on activation.
Connect to terminal 12 (+) to obtain a POSITIVE reference point. For UL
installations, the trigger outputs shall be connected to devices rated to
operate over the range from 10.1 - 14.0 VDC at 50 mA.
Auxiliary Device Current Draw Worksheet
DEVICE
CURRENT DRAW
FOR EACH
NUMBER
OF UNITS
TOTAL CURRENT
FOR EACH
XK-104 Keypad
30mA
✴
6805 Keypad
60mA
✴
PIR
✴ ✴
Smoke Detector
✴ ✴
Glass Break Detector
✴ ✴
✴ ✴
✴ ✴
TOTAL CURRENT FOR ALL DEVICES =
(500mA max.)
NOTES:
✴
Only applies if device is powered from control terminals 12
(+) & 13 (-).
✴✴
If using devices such as PIRs, smoke detectors, etc., refer to
the specifications for that particular device's current draw. If
the total current draw exceeds 500mA, then use an
additional power supply.
Summary of Contents for XL-1S
Page 8: ...viii ...
Page 10: ...XL 1S Hookup and Installation Instructions 1 2 ...
Page 18: ...XL 1S Hookup and Installation Instructions 2 8 ...
Page 26: ...XL 1S Hookup and Installation Instructions 5 4 ...
Page 34: ...XL 1S Hookup and Installation Instructions 7 4 ...
Page 53: ...XL 1S Hookup and Installation Instructions 9 4 ...
Page 55: ...XL 1S Hookup and Installation Instructions 10 2 ...
Page 57: ...XL 1S Hookup and Installation Instructions 11 2 ...
Page 61: ...XL 1S Hookup and Installation Instructions B 2 ...
Page 63: ...XL 1S Hookup and Installation Instructions C 2 ...
Page 65: ...XL 1S Hookup and Installation Instructions D 2 ...
Page 69: ...XL 1S Hookup and Installation Instructions F 2 ...
Page 71: ... 1 9 l N9471V1 06 98 Copyright 1998 PITTWAY CORPORATION ...