41
CAUSE
SOLUTION
LCD DISPLA
Y
PRODUCT OUT
DEFROSTING
READY TO SERVE
NOT READY
SOLUTIONS
Replace empty syrup (BIB) container
.
(A) Replace empty CO
2
tank.
(B) Check water (H
2
O) supply.
(A, B) Restart unit by pushing “
Def
” button,
then “
Run
” button on both sides.
(A) Unit is in “sleep” mode
(B) Unit is turned of
f
W
A
RNING LIGHTS ST
AT
US
Out of syrup for barrel
RED
light flashing
(Any single barrel)
All
RED
lights flashing
(All barrels)
RED
light continuously
on (any barrel)
All
RED
lights on and
beaters not turning
No lights and unit is not
running
No lights and unit is not running
(A) Out of CO
2
(B) Out of water (H
2
O)
Unit defrosting
Unit in first freeze
after defrost
Unit is not plugged in or
breaker has been tripped
No message
on display
(A)
(B)
No message
on display
If on defrost during peak draw
, cancel
defrost by pushing “
Def
”, then push “
Run
”.
W
ait until unit completes defrost and
freeze down cycle.
Plug in unit or reset circuit breaker
.
Then
restart unit.
(A)
(B)
Lights flashing
DEFROSTING
NOT READY
Light flashing
NOT READY
All barrels light flashing
and beaters not turning
NOT READY
All barrels
Lights flashing
PRODUCT OUT
NOT READY
DO NO
T
USE
WHEN
LIT
DO NOT USE
Any single barrel
Lights flashing
PRODUCT OUT
NOT READY
Summary of Contents for FBD562
Page 49: ...49 14 8 LOWER BOARD SCHEMATIC FBD 562 562 ELECTRICAL BOX SCHEMATIC ...
Page 50: ...50 14 9 UPPER BOARD SCHEMATIC FBD 563 563 SCHEMATIC UPPER BOARD ...
Page 51: ...51 14 10 LOWER BOARD SCHEMATIC FBD 563 563 ELECTRICAL BOX SCHEMATIC ...
Page 52: ...52 14 11 UPPER BOARD SCHEMATIC FBD 564 564 SCHEMATIC UPPER BOARD ...
Page 53: ...53 14 12 LOWER BOARD SCHEMATIC FBD 564 564 ELECTRICAL BOX SCHEMATIC LPB1 ...