NOTE:
H2O readout will be 15-20
psi higher on the readouts.
Keep regulated pressure at
70-72 psig.
(Item 13.34 continued from previous page.)
F. Syrup Transducer problem.
F. Check syrup pressure readouts
for 70-72 psig. If not within 2 psi,
adjust regulator and/or check
transducer. Replace transducer, if
necessary.
G. Lower Board problem.
G Check lower power board for +5,
+15, and –15 indicator lights. If
green lights are not energized,
replace board, if necessary.
H. Upper Board Problem.
H. Circuits within Main Control (Upper)
Board electronics read transducer
pressures. Replace Main Control
(Upper) Board, if necessary.
13.35
H2OOUT,
Water Out
A. Unit receiving no water.
A. Assure water is turned on.
B. Restriction in lines.
B. Assure all lines are free of crimps
or
restrictions.
C. Regulator pressures (unit
C. Check pressure readouts (H
2
O and
water pump) too low or CO
2
CO
2
) for 70-72 psig. Adjust
out.
regulators, if necessary. Replenish
CO
2
supply.
D. Water Pump failure.
D. Check pump and replace, if
necessary.
E. Water pressure too low,
E. Reroute water to maximize supply
can’t keep up with unit
pressure. Install Water Booster, if
demand.
necessary.
F. Water Transducer problem.
F. Check water pressure readout for
70-75 psig. If not within 2 psi, adjust
regulator and/or check transducer.
Replace transducer, if necessary.
G. Lower Board problem.
G. Check lower power board for +5,
+15, and –15 indicator lights. If
green lights are not energized,
replace board if necessary.
H. Upper Board Problem.
H. Circuits within Main Control (Upper)
Board electronics read transducer
pressures. Replace Main Control
(Upper) Board, if necessary.
13.36
CO2OUT,
CO2 Out
A. Unit receiving no CO
2
. A.
Assure
CO
2
supply is not empty or
turned
off.
B. Restriction in lines.
B. Assure all lines are free of crimps
or
restrictions.
C. Regulator pressures (to unit
C. Check pressure readout ( CO
2
) for
and syrup pumps) too low.
70-72 psig. Adjust regulators, if
necessary.
D.
CO
2
can’t keep up with
D. Increase CO
2
line size to maximize
unit demand.
supply pressure or supply unit
dedicated
CO
2
source. Bulk
regulator must be 105 psig
minimum,
CO
2
line must be tied to
main branch of bulk system, with
step down regulator (set 70-72 psig)
between tie-in and unit
E.
CO
2
Transducer problem.
E. Check CO
2
pressure readout for
70-72 psig. If not within 2 psi, adjust
regulator and/or check transducer.
Replace transducer, if necessary.
F. Lower Board problem.
F. Check lower power board for +5,
+15, and –15 indicator lights. If
green lights are not energized,
replace board if necessary.
(Item 13.36 continued on next page.)
37
TROUBLE CAUSE
REMEDY
Summary of Contents for FBD562
Page 49: ...49 14 8 LOWER BOARD SCHEMATIC FBD 562 562 ELECTRICAL BOX SCHEMATIC ...
Page 50: ...50 14 9 UPPER BOARD SCHEMATIC FBD 563 563 SCHEMATIC UPPER BOARD ...
Page 51: ...51 14 10 LOWER BOARD SCHEMATIC FBD 563 563 ELECTRICAL BOX SCHEMATIC ...
Page 52: ...52 14 11 UPPER BOARD SCHEMATIC FBD 564 564 SCHEMATIC UPPER BOARD ...
Page 53: ...53 14 12 LOWER BOARD SCHEMATIC FBD 564 564 ELECTRICAL BOX SCHEMATIC LPB1 ...