15
SAN ANTONIO, TEXAS
SIDE ONE
SIDE TWO
SIDE THREE
SIDE FOUR
FILL
BEATER
RUN
DEF.
OFF
FILL
BEATER
RUN
DEF.
OFF
FILL
BEATER
RUN
DEF.
OFF
FILL
BEATER
RUN
DEF.
OFF
CANCEL
SELECT
BACK
FWD
FBD564 Contols
Figure 7.1c
7. OPERATION OF THE DISPENSER
7.1
OPERATING ELECTRONIC CONTROLS
A. The electronic machine controls are designed to provide a logical sequence of operation with a
minimum of written instruction. System operating parameters are selected and set from a menu.
B. Buttons (see Figures 7.1a, 7.1b and 7.1c).
1. Each chamber has five (5) active buttons. They are labeled FILL, BEATER, RUN, DEF (defrost),
and OFF.
2.
Each button operates a double acting switch.
Pressing the button once activates the
process. Pressing the button a second time deactivates the process.
Take care not to double
press the buttons when first activating a process
.
The RUN button initiates the freeze process. After pressing this button, the
beater motors will run for five (5) seconds before the compressor starts. Run also
maintains the flow of product into the chambers when needed. You should always
press the DEFROST button first to baseline the unit.
The OFF button turns off all the machine’s refrigeration and chamber refill
systems. All of the electronic controls are still active.
The BEATER button activates the beaters inside the freezing chambers. The
beaters can be activated to mix the slurry.
NOTE:
The beaters start automatically when the RUN or DEF buttons are pressed.
The DEF button allows the user to manually defrost chamber. Because
the unit automatically defrosts during the day, it is not necessary to defrost
manually. However, this button provides the option to do so if desired.
The FILL button activates the solenoid valves that allow product to flow into the
freezing chambers (providing the pressure in the barrel is low enough to allow a
fill). Each chamber should be filled to 90% of chamber capacity (level with the
relief vent valves) prior to start-up.
RUN
OFF
BEATER
DEF
FILL
Summary of Contents for FBD562
Page 49: ...49 14 8 LOWER BOARD SCHEMATIC FBD 562 562 ELECTRICAL BOX SCHEMATIC ...
Page 50: ...50 14 9 UPPER BOARD SCHEMATIC FBD 563 563 SCHEMATIC UPPER BOARD ...
Page 51: ...51 14 10 LOWER BOARD SCHEMATIC FBD 563 563 ELECTRICAL BOX SCHEMATIC ...
Page 52: ...52 14 11 UPPER BOARD SCHEMATIC FBD 564 564 SCHEMATIC UPPER BOARD ...
Page 53: ...53 14 12 LOWER BOARD SCHEMATIC FBD 564 564 ELECTRICAL BOX SCHEMATIC LPB1 ...