www.fastech.co.kr
Other Operation Functions
42
Other Operation Functions
8.
Position Table (PT) Operation Examples
8-1.
Input ‘PT A0~ PT A7’ signals to set PT number.
Input ‘PT Start’ number to execute speed control operation. For more information, refer to
「User Manual – Position Table Function」
.
【
Position Table Setting
】
PT
No
Command
type
Position
Low
Speed
High
Speed
Accel.
time
Decel.
time
Wait
time
Continuous
Action
JP Table
No.
0
3
10000
1
2500
50
300
0
1
1
1
3
1000
1
500
-
-
0
1
2
2
3
5000
1
1500
50
300
300
0
3
3
3
-2500
1
1000
300
300
0
0
-