
www.fastech.co.kr
Control I/O signal
36
13) JPT(Jump Position Table)
Start Input
To select motion pattern (position table number) to be subsequently executed according to
input signal conditions. The difference from Paragraph 「12) ‘JPT Input0~Input2 Input」 is:
1)
PT number to be jumped must be composed to 10XXX;
2)
Next motion is not executed until ‘JPT Start’ is set to ON. If ‘Wait Time’ value of PT data
is more than ‘0’, the time lapses additionally and then next motion is executed.
【Example】
PT 14 Data
PT Number
…
Wait
Time
JP Table No
JPT 0
JPT 1
JPT 2
14
…
500
10015
10115
10116
10255
Summary of Contents for Ezi-Step II Plus-E
Page 1: ... Rev 03 User Manual Text ...
Page 8: ...www fastech co kr Specifications of the Drive 8 ...
Page 11: ...www fastech co kr 11 Specifications size of the Motor Motor Size 3 2 ...
Page 12: ...www fastech co kr Specifications size of the Motor 12 ...
Page 17: ...www fastech co kr 17 Configuration 2 86 mm motor drive ...
Page 19: ...www fastech co kr 19 Configuration 2 86 mm Motor Drive ...
Page 67: ...www fastech co kr 67 Appendix Brake Installed Motor Specification and Size 12 3 ...