www.fastech.co.kr
Appendix
62
Appendix
12.
Option for Interface Board: Ezi-STEPⅡ Plus-E
12-1.
■ Interface Board
All Input & Output signals are connected through the connector CN1.
■
Extension cable for Interface Board
It is used to connect the CN1 terminal block of the drive to the interface board.
Item
Length[m]
Remark
CIFD-S-□□□F
□□□
Normal cable
CIFD-S-□□□M
□□□
Robot cable
□ is cable length.
The unit is 1[m] , maximum length is 20[m].
The cable connection is 1:1 straight type.
Type
Item
Interface Board
(Terminal Block)
TB-Plus
No. of CN1
Signal
name
Signal name of
TB-Plus
1
Limit+
L+
2
Limit-
L-
3
Origin
ORG
4
IN1
I1
5
IN6
I6
6
IN7
I7
14
IN2
I2
15
IN3
I3
16
IN4
I4
17
IN5
I5
18
IN8
I8
19
IN9
I9
No. of CN1
Signal
name
Signal name of
TB- Plus
7
COMP
CO
8
OUT1
O1
9
OUT2
O2
10
OUT3
O3
11
OUT4
O4
12
OUT5
O5
13
OUT6
O6
20
OUT7
O7
21
OUT8
O8
22
OUT9
O9
23
Brake+
B+
24
Brake-
B-
Use
Item
Specification
Maker
Terminal Block
connector
Connector
DB-26 male type
Drive
connector(CN1)
Connector Housing
10126-30000VE
3M
Backshell
10320-52AO-008
3M
Summary of Contents for Ezi-Step II Plus-E
Page 1: ... Rev 03 User Manual Text ...
Page 8: ...www fastech co kr Specifications of the Drive 8 ...
Page 11: ...www fastech co kr 11 Specifications size of the Motor Motor Size 3 2 ...
Page 12: ...www fastech co kr Specifications size of the Motor 12 ...
Page 17: ...www fastech co kr 17 Configuration 2 86 mm motor drive ...
Page 19: ...www fastech co kr 19 Configuration 2 86 mm Motor Drive ...
Page 67: ...www fastech co kr 67 Appendix Brake Installed Motor Specification and Size 12 3 ...