To program:
pick up the handset (dialling tone);
dial the access code 333307 (day) or 333309 (night);
- (only FT105P) – dial 5 digits to program 5 extensions (see Table). Always dial a
number of 5 digits even if extensions are less than 5.
- (only FT208P) – dial 8 digits to program 8 extensions (see Table). Always dial a
number of 8 digits even if extensions are less than 8.
wait for the acknowledgement tone and hang up.
day
night
FT105P 333307xxxxx
333309xxxxx
FT208P 333307xxxxxxxx
333309xxxxxxxx
3333 07 3 1 2 2 3 1 0 2
extension 41 can receive calls from both external lines
extension 42 can receive calls from external line 1
extension 43 can receive calls from external line 2
extension 44 can receive calls from external line 2
extension 45 can receive calls from both external lines
extension 46 can receive calls from external line 1
extension 47 can only receive internal calls
extension 48 can receive calls from external line 2
Example: if the code below has been dialled, in day service:
4 3
I
N
T
E
R
C
O
M
S
FT
105P
208P
RELAY ACTIVATION
This function allows for activating the 4 relays of the intercom card ES60 or ES65 (or
actuator card) for auxiliary services (lights, thermostats, heating and air conditioning
installations, etc.).
Note
Only one card at time can be added in the PABX (either intercom or actuator).
For installing the card and connection terminal block see on pages 37 and 38.
Transfer an intercom call
To transfer an intercom call to an enabled user:
hang up to suspend the intercom conversation
pick up the handset
call the desired extension and hang up after the message
The called user can:
press FLASH
dial 6
- conversation with the external intercom station starts
Relay activation during conversation
This function allows for activating the relays no.1 and 2 of the intercom card ES60 or ES65
in order to operate electrical locks, turn on the staircase lighting, etc.
During the conversation with the external intercom station:
press FLASH
- dialling tone
dial the number of the relay to be activated:
1 immediate enabling of relay 1
for about 3 seconds
2 immediate enabling of relay 2
for about 3 seconds
3 enabling of relays 1 and 2 in sequence.*
* Relays 1 and 2 are not enabled at the same time, in order not to overcharge the intercom
power supply unit when used to activate electrical locks. Relay 2 is enabled with about 3
sec. delay.
Flash+1
Flash+6
Flash+2
Flash+3
Summary of Contents for FT 105P
Page 1: ...Installation Programming and User s Manual FT 105P and FT 208P PABX February 2003 Mi 2236 gb...
Page 2: ...ACI Srl FARFISA Intercoms reserves the right to modify the products illustrated at any time...
Page 55: ...ACI Srl FARFISA Intercoms reserves the right to modify the products illustrated at any time...