4
MAINTENANCE
No parts of the PABX can be replaced directly by the user.
In case of failure, contact the nearest Farfisa Service Center or distributor.
In the meantime, the PABX can be operated in emergency mode (see next chapter), by
placing the switch on O.
EMERGENCY
In case of power failure, the following lines can be used to make/receive calls:
for FT105P
extension 41
for FT208P
extension 41 for external line 1
extension 42 for external line 2
An EEPROM memory guarantees the preservation of the general programming data (or
system data) and restore them when the power is restored.
TECHNICAL DATA
FT105P
FT208P
Supply voltage (+6 ÷ -10%):
230V
230V
Maximum power consumption:
16W
18W
Power consumption in stand-by:
10W
10W
Input protection fuse:
0,315A
0,315A
Maximum distance of an extension line
with 0.6 mm
2
telephone pair:
350m
350m
Dimensions:
226x254x66
226x254x66
Weight:
1.3 Kg
1.4 Kg
Operating temperature:
0°÷40°C
0°÷40°C
Maximum humidity permitted:
85%RH
85%RH
Number of external lines:
1
2
Number of extension lines:
5
8
Number of DTMF receivers:
1
2
Simultaneous internal conversations:
2
2
Simultaneous external conversations:
1
2
Paging communication:
1
1
Intercom calls (additional card):
1 o 2
1 o 2
Preservation of data in case of power failure:
EEprom
EEprom
Extension lines in emergency mode:
41
41 e 42
Extension line for facsimiles, modems, answering machines: 45 *
48 *
Microprocessor control with recorded program
Solid-state switching matrix
2-wire internal telephone network
* The other extension lines can also be used but in this case. The use of the general call
function is not recommended.
I
N
S
T
A
L
L
A
T
I
O
N
FT
105P
208P
4 9
T
A
B
L
E
S
FT
208P
PROGRAMMING TABLE
Model FT208P
Access
Number to be stored
See
SERVICE
code
for each extension
page
41 42 43 44 45 46 47 48
Enables day outgoing phone conversat.
333302
_
_
_
_
_
_
_
_
6
Enables night outgoing phone conversat. 333304
_
_
_
_
_
_
_
_
6
Enables day incoming phone conversat.
333303
_
_
_
_
_
_
_
_
8
Enables night incoming phone conversat. 333305
_
_
_
_
_
_
_
_
8
Enables day outgoing calls
333306
_
_
_
_
_
_
_
_
11
Enables night outgoing calls
333308
_
_
_
_
_
_
_
_
11
Enables day incoming calls
333307
_
_
_
_
_
_
_
_
9
Enables night incoming calls
333309
_
_
_
_
_
_
_
_
9
Enables day intercom access
333310
_
_
_
_
_
_
_
_
40
Enables night intercom access
333312
_
_
_
_
_
_
_
_
40
Enables day intercom calls
333311
_
_
_
_
_
_
_
_
41
Enables night intercom calls
333313
_
_
_
_
_
_
_
_
41
Clearing or FLASH time
333314
_
_
_
_
_
_
_
_
12
Enables extension dialling control
333315
_
_
_
_
_
_
_
_
18
Service enabling
333316
_
_
_
_
_
_
_
_
13
SYSTEM PROGRAMMING
Access
Number to be stored
See
code
page
DEC/DTMF – DTMF tones – Intercom
333317
_
_
_
_
_
_
_
_
14
D.I.S.A.
Enable Caller ID
333318
_
_
_
_
_
_
_
_
33
Overcoming the selective control
333319
_
_
35
External 1 password
333320
_
_
_
_
44
External 2 password
333321
_
_
_
_
44
1
st
blocking number for dialling control
333322
_
_
_
_
_
_
_
_
17
8
th
blocking number for dialling control
333329
_
_
_
_
_
_
_
_
17
1
st
number enabled
333330
_
_
_
_
_
_
_
_
16
8
th
number enabled
333337
_
_
_
_
_
_
_
_
16
Returning to the base programming
333399
5
Programming PABX directory
222200,...,39
34
Summary of Contents for FT 105P
Page 1: ...Installation Programming and User s Manual FT 105P and FT 208P PABX February 2003 Mi 2236 gb...
Page 2: ...ACI Srl FARFISA Intercoms reserves the right to modify the products illustrated at any time...
Page 55: ...ACI Srl FARFISA Intercoms reserves the right to modify the products illustrated at any time...