6.1
Maintenance: Clean the Pass-Through Anchor with water and mild detergent. Do not allow excessive build-up of dirt, paint or other
agents that may cause damage or hardening of the web fibers on any webbing. Hardening of the fibers of the web from external
elements may result in a loss of strength or alter the properties of the web in a manner that could cause the Pass-Through Anchor to fail
or to operate and perform correctly.
6.2
Proper Care
•
Keep the Pass-Through Anchor clean and free of contaminants, this will greatly increase the service life.
•
Mold and mildew due to damp storage will reduce the service life.
•
Use a damp rag and a mild soap and water solution to clean the hardware. Wipe the hardware dry with a clean soft cloth.
• DO NOT use heat to dry.
• DO NOT use any solvents or petroleum products to clean this anchor.
• DO NOT attempt to repair or modify this Pass-Through Anchor or any of its components. Such attempts will void the warranty
and may result in serious injury or death.
6.3
Storage: Store in a clean, dry and chemical free environment and kept out of direct sunlight.
6.0 Maintenance, Service, and Storage
7.0 Inspection
7.1 Pre-Use Inspection: Please review the Pre-Use Inspection guidelines in Section 5.4 for inspection requirements.
7.2 Inspection Frequency: FallTech requires all fall protection equipment to be inspected by a competent person other than the user at
least once each year or more frequently if the conditions exist. FallTech strongly recommends that a competent person conducts a hazard
assessment of the environment and determines the length of the inspection intervals due to the site conditions. The annual inspection
shall be recorded on an inspection log, including all deficiencies. This inspection should also be used as an opportunity to train any
authorized persons with respect to deficiencies that they have failed to observe on their daily inspections.
Inspection Frequency
Type of Use
Application Examples
Example Conditions of Use
Worker Inpection
Frequency
Competent
Person
Inspection
Frequency
Infrequent to
Light Use
Rescue and confined space,
factory maintenance
Good storage conditions, indoor or infre-
quent outdoor use, room temperature, clean
environments
Before each use
Annually
Moderate to
Heavy Use
Transportation,
residential constrution,
utilities, warehouse
Fair storage conditions, indoor and extended
outdoor use, all temperatures, clean or dusty
environments
Before each use
Semi-annually to
annually
Severe to
Continuous
Use
Commercial
construction, oil and gas,
mining, foundry
Harsh storage condtions, prolonged or con-
tinuous
outdoor use, all temperatures, dirty environ-
ments
Before each use
Quarterly to
semi-annually
7.3 Inspection Results: If an inspection reveals defects in or damage to the equipment, inadequate maintenance or activated fall
indicators, remove the equipment from service.
MANC03 Rev B
040320
9