background image

BIO Pellet Stoves

 

6

 

 

 

These positions are de

ned by Document J of the Building Regulations.

 

Seek specialist advice if installing 

in a dwelling with a thatched roof

 

Adjacent 

Building

 

Terminal

 

Flue

 

Horizontal 

Measurement

 

A

 

D

 

150mm 

Max

 

B

 

Vertical 

Measurement

 

C

 

Adjacent 

Building

 

Insulation

 

The datum for vertical measurement is the point of 

discharge of the 

ue from either the point of disxcharge 

ofn the 

ue or 150mm above insulation, whichever is 

the lower.

 

 

If the chimney is believed to have previously served an open fire it must be swept a second time   

within a month of regular use after installation to clear any soot falls that may have occurred due to 

difference in combustion levels. The flue exit from the building must comply with local building control 

rules. Do not connect or share the flue or chimney system with another heating appliance. Do not 

connect to systems containing large voids or spaces over 230mm square.

 

 

Chimney 

Suitable access must be provided to enable the collection and removal of debris. The flue must be 

swept and inspected when the appliance is installed. The flue draught must be checked with all 

windows and doors closed and any extraction fans in this, or adjoining rooms, running at maximum 

speed (see next section for additional ventilation requirements). 

 

 

Max. draught = 2.0mm Wg, 

 

Min. draught = 1.0mm Wg 

 

The draught, which is necessary for the different models of pellets stoves, is 8pa to 12pa (0,08 to 

0,12mbar). 

 

 

 

 

 

Point where the flue passes through weather surface (Note 1 & 2)

 

Clearances to the flue outlet

 

A

 

At or within 600mm of the ridge

 

At least 600mm above ridge

 

B

 

Elsewhere on the roof (whether pitched or flat)

 

At least 2300mm horizontally from the nearest point on the 

weather surface (a) at least 100mm above  the  highest 

point of interaction of the chimney and weather surface;  or 

 

(b) at least as high as the ridge

 

C

 

Below (on a pitched roof) or within 2300mm horizontally to open- 

able rooflight, dormer window, or other opening (Note 3)

 

At least 1000mm above the top as the ridge

 

D

 

Within 2300mm of an adjoining or adjacent building, not beyond the 

boundary (Note 3)

 

At least 600mm above any part of the adjacent of the 

building wall

 

Note:

 

1.

 

The weather surface is the building external, such as it’s roof tiles or external  walls.

 

2.

 

A flat roof has a pitch less the 10º

 

3.

 

The clearance given for A or B, as appropriate, will also apply.

 

4.

 

A vertical flue fixed to an outside wall should be treated as equivalent to an inside flue emerging at the nearest edge of the roof

 

 

Chimney Maintenance

 

The chimney flue must be kept always clean: deposits of soot or incombustible oils reduce its section in size 

obstructing its draught, compromising the good functioning of the stove and if the residuals are big they can 

catch fire. The chimney flue and pot must be cleaned and checked by an expert at least once a year. Safety 

can be compromised by the non-cleaning. 

 

Summary of Contents for BIO80

Page 1: ...Maintenance and UserManual Pellet Stove BIO 80 BIO 80Q IMPORTANT This Appliance must be fitted by a HETAS METAC Qualified Installer...

Page 2: ...evel Automatic temperature control The internal thermostat senses the temperature environment and maintains it constant according to the settings inserted Control display The control display allows ad...

Page 3: ...of the installed product Fair will not be liable in the event of failure to respect these instructions This stove should be used for the purposes for which it was designed and made The manufacturer is...

Page 4: ...online stove output to room size calculator to help you decide the correct size space for your new stove My Pellet Stove doesn t turn OFF straight away This is because of the built in Cleaning feature...

Page 5: ...e the stove will extract the smoke given time turning off the stove while there is smoke will cause further smoke to build and not be extracted How to register my new stoves warranty Henley Stoves doe...

Page 6: ...block chimneys connecting flue pipe system must meet requirements of the Building Regulations We recommend a flexible flue liner system certified for use with solid fuel systems be used to improve sto...

Page 7: ...raught which is necessary for the different models of pellets stoves is 8pa to 12pa 0 08 to 0 12mbar Point where the flue passes through weather surface Note 1 2 Clearances to the flue outlet A At or...

Page 8: ...t 1m above the highest point of contact of chimney and roof Where the roof has a pitch of more than 10 on both sides and the outlet is at the ridge or within 600mm of it the height of the chimney or f...

Page 9: ...ermetically sealed doors and windows The situation can also be problematical when on the other hand there are drafts inside the room generated by fans in the kitchen or bathroom for example To avoid t...

Page 10: ...minimum thickness 0 5mm with a diameter of 80 mm or 100mm depending on the type of plant see picture 2 pag 6 you can not use pipes made of asbestos cement or flexible metal The pipes must be sealed wi...

Page 11: ...nly combustible material you can use You can find different kind of pellets with different characteristics and quality on sale We recommend to use pellets of good quality as that has great influence o...

Page 12: ...ion methods there must be a minimum distance of at least 20 cm from flammable objects sofas furniture wooden covering to the back and side of the stove and of 80 cm to the front where the fire door is...

Page 13: ...r for 2 3 days display A will show the number 3 so that the mechanical parts are able to settle into smooth running IMPORTANT Continuous operation of the stove at maximum power may shorten the expecte...

Page 14: ...t shows the state of the stove During functioning it shows the temperature chosen by the user During input setting it shows the parameter you are changing Starting To start the stove keep key P4 press...

Page 15: ...y B Fumes gas temperature To verify the fumes gas temperature at the outlet keep key P1 pressed for few seconds Switching off To switch off the stove keep P4 pressed Clean final will be displayed Duri...

Page 16: ...ON for example h 17 00 and turn OFF for example h 21 00 Press set P3 to confirm each time The situation could be the following Daily Program Start 1 Stop 1 Start 2 Stop 2 ON h 6 30 h 10 30 h 17 00 h...

Page 17: ...ms in order to avoid any crossover with weekend program M2 4 Go into setting M2 4 press set P3 decide ON OFF then confirm with set P3 If you decide ON the green light will switch ON This green light w...

Page 18: ...C delta T Menu 05 Menu 06 Menu 07 ATTENTION These menus functions are exclusively for the Technical service improper use can affect the functioning of the stove itself Menu 08 This Menu shall not be...

Page 19: ...lay A will show the message Off The remote control operates with a 12 Volt MN21 type battery The batteries should be removed from the device before it is disposed of and must themselves be disposed of...

Page 20: ...al 3 Hot Exhaust will appear on display the pellets stoking is decreased and the card makes the fumes extractor work at its minimum speed to take the temperature back to the setlimits If temperature...

Page 21: ...assistance for the maintenance to a qualified professional Do not do it can cause damage to the heater and its electrical and mechanical parts thereby affecting the operation safety and validity of th...

Page 22: ...lour if it is red that means it is weak if there is black smoke that means the brazier is dirty and it must be cleaned Ash draw cleaning Pic 14a IMPORTANT When refitting brazier ensure the above side...

Page 23: ...Average temperature fumes 92 5 167 C Mass flow fumes 2 9 5 5 g s Tank capacity 15 kg Volume to heat 150 240 m3 Air flow max 190 m3 h Autonomy 10 26 h Air fumes tubes diameter 40 80 mm Electrical inpu...

Page 24: ...verage temperature fumes 92 5 167 C Mass flow fumes 2 9 5 5 g s Tank capacity 15 kg Volume to heat 150 240 m3 Air flow max 190 m3 h Autonomy 10 26 h Air fumes tubes diameter 40 80 mm Electrical input...

Page 25: ...BIO Pellet Stoves 24 Wiring diagram N100 For the correct operation of the stove respect the polarity of the thermo couple...

Page 26: ...tions of the air inlet on the back of the stove brazier grid holes obstructed and or brazier box with too much hash exchanger pipes too dirty clean the extractor blades and its scroll see Maintenance...

Page 27: ...ll the tank Clean the brazier see Maintenance Empty the brazier and start again if the problem continues call a specialised technician Replace the plug Call a specialised technician Restart the stove...

Page 28: ...ot Have it cleaned immediately Pellets can burn thanks to the chimney flue depression without the aspirator Have it replaced immediately as it can be bad for your health Call a specialised technician...

Page 29: ...rtificate which should be completed correctly and accompanied by the receipt of purchase as proof The apparatus is not guaranteed in any way for non domestic use The same applies in the event that the...

Page 30: ...ise you to always refer to the dealer who sold the apparatus to you or to our nearest Technical Servicing Centre specifying the model and serial number and describing the problem Also bear in mind tha...

Page 31: ...Centre Work done on Specialised Technical Servicing Centre Material used Guarantee YES NO YES NO YES NO YES NO User s signature Segnature of TSC Material used Guarantee YES NO YES NO YES NO YES NO Us...

Page 32: ...Centre Work done on Specialised Technical Servicing Centre Material used Guarantee YES NO YES NO YES NO YES NO User s signature Segnature of TSC Material used Guarantee YES NO YES NO YES NO YES NO Us...

Page 33: ...BIO Pellet Stoves 31...

Page 34: ...BIO Pellet Stoves FAIR srl Via Lago di Costanza 24 Z I 36015 Schio Vicenza Italia Tel 39 0445 698000 Fax 39 0445 698100 www fair europe com info fair europe com Copyright Fair Rev 6 14 02 2019 EN...

Reviews: